Aube Technologies TH141A-HC-28 Instruction Manual Download Page 5

1.8 B

ATTERY INSTALLATION

When you first install the batteries in the TH141, the unit runs a sequence
of tests and a complete reset to zero, which last approximately 5
seconds. The screen should display the time and the day, as well as
the current temperature as follows:

It is normal for the displayed temperature to be higher than the room
temperature if your are holding the TH141 in your hands, It will return
to normal about one hour after installation on the wall. 
Mount the thermostat on the wall plate and screw it in place.

Even if the thermostat indicates that the batteries are good, it is recommended
to replace them once a year, at the beginning of the cold season.

12

2. ENTRY OF BASIC DATA

You may program the thermostat while holding it in your hands or once it is mounted
on the wall.

2.1 P

ROGRAMMING THE TIME AND DAY

1. Set the time using the Hour and Minute buttons.
2. Set the date using the Day button.

2.2 P

ROGRAMMING THE COMFORT

,

ECONOMIC AND VACATION SETTINGS

The Comfort

, Economic

and Vacation

settings respectively represent the

temperatures that you wish to have during the day

, at night

or while you are

away at work

, or while you are away for an extended period

. Since your

thermostat controls both heating and air-conditioning, and since the economic
settings are the opposite in both cases (reduction for heating temperature, increase
for air-conditioning), you must program the settings for heating and then for
air-conditioning.

13

1. To program your heating settings

a) Set your thermostat to the heating mode      using the Heat/Cool button.

b) To program the Comfort temperature, select the desired degree using the

buttons and press the button

until the

icon is displayed (app. 3 seconds).

c) To program the Economic temperature, select the desired degree using the

buttons and press the

button until the the

icon is displayed

(app. 3 seconds).

d) To program the Vacation temperature, select the desired degree using the

buttons and press on the

button until the

icon is displayed (app.

3 seconds). This setting is used by the telephone remote control.

e) Press the Manual/Auto button to exit this function and return to the normal

operating mode.

2.3 P

ROGRAM THE AIR

-

CONDITIONING SETTINGS

Set your thermostat to the air-conditioning mode

using the Heat/Cool button and

repeat operations b) to e).

14

3. OPERATING MODES

The TH141 offers two operating modes.

3.1 M

ANUAL

(    )

This mode allows you to maintain a constant temperature in the house.
1. To activate this mode, press the Manual/Auto button to display the      icon.
2. Set the desired temperature using the

buttons or select the pre-programmed

,        or       settings.

3.2 AUTO

MATIC

(     )

This mode executes your own programming. To activate this mode, press the
Manual/Auto button to display the

icon. The

or

icon indicates that the pro-

gram setting is active.

3.2.1 S

CHEDULE PROGRAMMING

The TH141 allows 4 setting changes for each day of the week. There are no pre-set
programs. The programs are tailored to perfectly adapt to your life style.
The principle is very simple. For each day, enter the time at which you wake up (P1),
the time you leave for work (P2), the time you arrive back home (P3) and the time you
go to bed (P4).

15

Summary of Contents for TH141A-HC-28

Page 1: ...6 1 2 Wire Heating System 4 1 6 2 3 Wire Heating System with Fan Control 5 1 6 3 3 Wire Air Conditioning System with Fan Control 5 1 6 4 4 Wire Heating and Air Conditioning System 5 1 6 5 5 Wire Heati...

Page 2: ...ide wall Avoid locations where there are a air drafts top of a staircase air outlet b dead air spots behind a door c direct sunlight d concealed chimneys or stove pipes 1 1 3 INSTALL AND CONNECT THE T...

Page 3: ...nnect the fan relay to terminal G 4 Connect the 24 V transformer to terminal Rh 5 Connect a wire between terminals Rh and Rc 5 1 6 5 5 WIRE HEATING AND AIR CONDITIONING SYSTEM 1 Connect the heating re...

Page 4: ...on electric heating 15 minute cycle for Central heating and air conditioning unit 20 minute cycle for Commercial unit 9 2 Conventional mode with anticipation If you want the conventional mode with ant...

Page 5: ...ing settings a Set your thermostat to the heating mode using the Heat Cool button b To program the Comfort temperature select the desired degree using the buttons and press the button until the icon i...

Page 6: ...he Manual Auto button to exit this function d Example 2 Comfort period Monday to Friday from 6 15 AM to 8 15 AM and from 5 00 PM to 10 00 PM Note It is faster to program the same schedule for every da...

Page 7: ...6 TELEPHONE CONTROLLER The TH141 incorporates a telephone controller interface which allows you to switch from the normal operating mode to the Vacation setting and vice versa using the telephone keyp...

Page 8: ...e Regulation Proportional or conventional Regulation periods 5 10 15 or 20 minutes 25 WARRANTY This product is guaranteed against workmanship defects for a two year period following the initial date o...

Page 9: ...25 10 02 920 141 000 00 1 A...