1. I

NSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1.1 Remove the Old Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Install the New Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Install and Connect the Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Identify the Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 Connect the Labelled Wires to the Thermostat . . . . . . . . . . . . . . . . . . . . 4
1.6 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.6.1   2- Wire Heating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.6.2   3- Wire Heating System with Fan Control. . . . . . . . . . . . . . . . . 5
1.6.3   3- Wire Air Conditioning System with Fan Control . . . . . . . . . . 5
1.6.4   4- Wire Heating and Air Conditioning System . . . . . . . . . . . . . 5
1.6.5   5- Wire Heating and Air Conditioning System . . . . . . . . . . . . . 6

1.7 Thermostat Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

a) 24 hrs. or 12 hrs. Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
b) Temperature in °C or °F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

c) Regulation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 - Proportional Adaptive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Regulation cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2 - Conventional  with anticipation . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Programmable Span . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

d) Heating Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.8 Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2. E

NTRY OF BASIC DATA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2.1 Programming the Time and Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Programming the Comfort, Economic and Vacation Settings . . . . . . . . . 13
2.3  Programming the Air Conditioning Settings . . . . . . . . . . . . . . . . . . . . . . 14

3. O

PERATING MODE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.1 Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.2.1 Schedule Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

a) To Program your Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Summary of Contents for TH141A-HC-28

Page 1: ...6 1 2 Wire Heating System 4 1 6 2 3 Wire Heating System with Fan Control 5 1 6 3 3 Wire Air Conditioning System with Fan Control 5 1 6 4 4 Wire Heating and Air Conditioning System 5 1 6 5 5 Wire Heati...

Page 2: ...ide wall Avoid locations where there are a air drafts top of a staircase air outlet b dead air spots behind a door c direct sunlight d concealed chimneys or stove pipes 1 1 3 INSTALL AND CONNECT THE T...

Page 3: ...nnect the fan relay to terminal G 4 Connect the 24 V transformer to terminal Rh 5 Connect a wire between terminals Rh and Rc 5 1 6 5 5 WIRE HEATING AND AIR CONDITIONING SYSTEM 1 Connect the heating re...

Page 4: ...on electric heating 15 minute cycle for Central heating and air conditioning unit 20 minute cycle for Commercial unit 9 2 Conventional mode with anticipation If you want the conventional mode with ant...

Page 5: ...ing settings a Set your thermostat to the heating mode using the Heat Cool button b To program the Comfort temperature select the desired degree using the buttons and press the button until the icon i...

Page 6: ...he Manual Auto button to exit this function d Example 2 Comfort period Monday to Friday from 6 15 AM to 8 15 AM and from 5 00 PM to 10 00 PM Note It is faster to program the same schedule for every da...

Page 7: ...6 TELEPHONE CONTROLLER The TH141 incorporates a telephone controller interface which allows you to switch from the normal operating mode to the Vacation setting and vice versa using the telephone keyp...

Page 8: ...e Regulation Proportional or conventional Regulation periods 5 10 15 or 20 minutes 25 WARRANTY This product is guaranteed against workmanship defects for a two year period following the initial date o...