background image

7

6.  Check that the “summer / winter” valve is in the proper   
 

position for the temperature of the incoming water.

Water Temperature Too low at lower Water flow 
rates

1.  Check that the “summer / winter” valve is in the proper   
 

position for the temperature of the incoming water.

2.   Be sure to momentarily turn water flow to high, then back  
 

to the lower flow when turning on a water faucet. This will  

 

bring the gas flow to the required higher setting.

Water Temperature is Too Hot or no Temperature 
control.

1.   Fuel tank regulator is set too high and manifold pressure  
 

as described above Have the regulator checked by a    

 

qualified technician.

2.   Check that the “summer / winter” valve is in the proper   
 

position for the temperature of the incoming water.

3.   Water flow too low for incoming water temperature.

low Heat rise and excessive Water flow is required 
To Trigger Water Heater

If you find that your heater requires excessive flow to activate it 
(much over .5 gallon per minute), it is likely that you have cold 
water bleeding into the hot water side of your water system.

1.  Check that valves and faucets are closed when not in use.  
 

If there is an on/off button on your showerhead, always   

 

turn the water valves off after the shower to prevent cold  

 

water from bleeding into the hot water system. This will   

 

keep the heater from functioning properly.

2.  Be sure that the bypass valve at the water plumbing  

 

 

connections is in the “off” position. An open valve can    

 

also permit water to bypass heater, causing it not to fire.

if any problem persists, contact an authorized service 
center or atwood.

ATWOOD WATer HeATer lIMITeD

WArrAnTy

Atwood Mobile Products warrants to the original owner and subject 
to the below mentioned conditions, that this product will be free of 
defects in material or workmanship for a period of two years from the 
original date of purchase. Atwood’s liability hereunder is limited to 
the replacement of the product, repair of the product, or replacement 
of the product with a reconditioned product at the discretion of the 
manufacturer. This warranty is void if the product has been damaged 
by accident, unreasonable use, neglect, tampering or other causes 
not arising from defects in material workmanship.
This warranty extends to the original owner of the product only and 
is subject to the following conditions:
1.  For a period of two years from the date of purchase, Atwood  
 

will replace the complete water heater if the heat exchanger 

 

leaks due to corrosion. This warranty includes reasonable labor  

 

charges required to replace the complete water heater.

2.   For two years from the date of purchase, Atwood will repair or
 

replace any part defective in material or workmanship. This

 

warranty includes reasonable labor charges, required to remove  

 

and replace the part.

 

Service calls to customer’s location are not considered part  

 

of these charges and are, therefore, the responsibility of the  

 

owner.

3.   This warranty does not cover the following items classified as  
 

normal maintenance:

 

  a.  adjustment of gas pressure

 

  b.  cleaning or replacement of burner orifices

 

  c.  cleaning or adjustment of burner assembly

 

  d.  cleaning or adjustment of flue

 

  e.  adjustment of pressure relief valve

4.  In the event of a warranty claim, the owner must contact, in  
 

advance, either an authorized Atwood Service Center or the  

 

Atwood Service Department. Warranty claim service must be  

 

performed at an authorized Atwood Service Center (can be found  

 

online @ www.atwoodmobile.com) or as approved by the  

 

Consumer Service Department, Atwood Mobile Products,

 

1120 North Main St., Elkhart, IN 46514 USA.    

 

Phone: (866-869-8116).

5.   Return parts (or water heater) must be shipped to Atwood  
 

“Prepaid”. Credit for shipping costs will be included with the  

 

warranty claim. The defective parts (or water heater) become the  

 

property of Atwood Mobile Products and must be returned to the  

 

Consumer Service Department, Atwood Mobile Products,

 

6320 Kelly Willis Road, Greenbrier, Tn 37073 USA.

6.  This warranty applies only if the unit is installed according to the
 

installation instructions provided and complies with local and  

 

state codes.

7.  The warranty period on replacement parts is the unused portion  
 

of the original warranty period or ninety (90) days, whichever is  

 

greater.

8.   Damage or failure resulting from misuse (including failure to seek    
 

proper repair service), misapplication, alterations, water damage,  

 

or freezing are the owner’s responsibility.

9.   Atwood does not assume responsibility for any loss of use of  
 

vehicle, loss of time, inconvenience, expense for gasoline,  

 

telephone, travel, lodging, loss or damage to personal property or  

 

revenues. Some states do not allow the exclusion or limitation of  

 

incidental or consequential damages, so the above limitations or  

 

exclusions may not apply to you.

10. Any implied warranties are limited to two (2) years. Some states  
 

do not allow limitations on how long an implied warranty lasts, so  

 

the above limitation may not apply to you. This warranty gives  

 

you specific legal rights and you may also have other rights  

 

which vary from state to state.

11. Replacement parts (components) purchased outside of the  
 

original water heater warranty carries a 90 day warranty. This  

 

includes the part at no charge and reasonable labor charges to  

 

replace it. This Atwood heater is designed for use in recreational  

 

vehicles for the purpose of heating water as stated in the “data  

 

plate” attached to the water heater. Any other use, unless  

 

authorized in writing by the Atwood Engineering Department,  

 

voids this warranty.

Summary of Contents for MPD 90222

Page 1: ...Input in 1000 s Btu 01__________ Generation m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV DO NOT vent ...

Page 2: ...ior to erecting the walls NOTE Parts bagged and included with the unit include corner filler brackets flue screen and cover hole bushing 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To install the unit on carpeting assure the addition of m...

Page 3: ...MP 12 VDC GAS ORANGE FROM W H 9 Place flue screen from parts bag over end of flue tube Place the access door on the lower flange pins aligning the holes in the bottom of the door Carefully close the top edge of the door being careful to align the flue opening with the flue tube and screw in the fastener Push snap plastic bushing supplied in parts bag into the hole in the door front 10 The applianc...

Page 4: ...ARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke of have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running Drain water heater at regular ...

Page 5: ...0 Gas Inlet Tube 90273 11 Ignition Control 90274 12 Flue Outlet Screen 90275 13 Flue Tube 90276 14 Pressure Switch 90277 15 Blower Assembly 90278 16 Fan Base 90279 17 Flue Hood Assembly 90280 18 Case Assembly 90281 19 Heat Exchanger 90282 20 ECO 90283 21 Plug 90284 ITEM DESCRIPTION PART 22 Orifice 72 45 000 Btu 90285 23 Orifice 71 50 000 Btu 90286 24 Orifice 0 27 55K for PT 3392 Inquire 25 Pressur...

Page 6: ...is sparking from the probe to the burner Bend ignition wire to adjust to proper gap or contact Atwood or you re nearest authorized service representative 5 Check that there are no cuts or breaks in the wire Align it so that it is not in contact with anything but the terminal 6 Be sure that the power vent fan has 12 volts to it when there is water flowing and there are no obstructions in the flue p...

Page 7: ...art defective in material or workmanship This warranty includes reasonable labor charges required to remove and replace the part Service calls to customer s location are not considered part of these charges and are therefore the responsibility of the owner 3 This warranty does not cover the following items classified as normal maintenance a adjustment of gas pressure b cleaning or replacement of b...

Page 8: ...8 intentionally left blank ...

Page 9: ...ou les fuites n ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 45________________ Entrée en milliers de BTU 01__________ Génération m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véhicules récréa...

Page 10: ...ompte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces ensachées et venant avec l unité de remplissage comprennent le support de fixation la grille du conduit d air et la douille du trou de couverture 1 Localisez le chauffe eau sur le plancher du véhicule à l emplacem...

Page 11: ...alve doit avoir un réglage de la pression maximale qui ne doit pas dépasser 100 lb po Installez le remplacement de la valve dans l orifice prévu et désigné à cet effet sur le chauffe eau Adaptateur Installation dans l ouverture d un chauffe eau de 10 gallons standard avec la trousse et l adaptateur pour une grande porte 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière ...

Page 12: ...ndre le chauffe eau couper l eau 7 En cas de surchauffe ou si l approvisionnement en gaz ne s arrête pas fermer l interrupteur On Off ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type BLEU DU CHAUFFE EAU LAMPE DE VERROUILLAGE 12 V c c GAZ ORANGE...

Page 13: ...igé remplacer le fusible de 2 ampères par un mini fusible ATO Ne pas installer un fusible de plus de 3 ampères Si le fusible est bon et que l unité ne fonctionne pas vérifier si l appareil ne présente pas une tension excessive plus de 14 volts Fonctionnement hivernal et hivernage du chauffe eau Il n est pas recommandé d utiliser les systèmes d eau pendant l hiver Tout gel du chauffe eau ou des aut...

Page 14: ...e d allumage 90274 12 Grille du conduit d air 90275 13 Tube d appel d air 90276 14 Pressostat 90277 15 Ens ventilateur 90278 16 Base ventilateur 90279 17 Ens hotte du conduit d air 90280 18 Ens du boîtier 90281 19 Échangeur de chaleur 90282 20 ECO 90283 21 Fiche 90284 ARTICLE DESCRIPTION Nº DE PIÈCE 22 Orifice nº 72 45 000 BTU 90285 23 Orifice nº 71 50 000 BTU 90286 24 Orifice 0 27 55K pour PT nº ...

Page 15: ...e qui évitera son déclenchement Il n y a pas d allumage lorsque l eau est activée le ventilateur est en marche 1 Assurez vous que la soupape de gaz du réservoir est à On qu il y a du gaz dans le réservoir et que la conduite de gaz est complètement purgée d air 2 Assurez vous que le débit d eau est d au moins de 0 5 gal minute 3 Vérifiez si le câble d allumage est branché dans la tour d allumage su...

Page 16: ...clusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États n autorisent pas les restrictions sur la durée d une garantie implicite par conséquent il est possible que les restrictions précédentes ne s appliquent pas à vous Cette garantie vous accorde des droits légaux spécifiques et vous pouvez aussi avoir d autres droits pouva...

Page 17: ...r cooler hot water temperatures the modulating valve can be adjusted clockwise toward the MIN position One should use caution not to force the valve adjustment beyond the MAX and MIN points Some factors relating to output performance are 1 City or Park Water Service incoming pressures 2 Obstructions or restrictions in the water system including water bypass valves in vehicles The bypass valve in y...

Reviews: