background image

19

ENGLISH, FRANCAIS

(et Canada)

•Installation  •Operation

Effective 9/21/04

LITERATURE NUMBER

MPD 31492

hydro flame

TM

Model 1H2C

Digital Thermostat

FOR STANDARD FURNACES

&

A/C SYSTEMS

SPECIFICATIONS

Operating Voltage ........................ 9VDC to 18VDC
Current Consumption at 12VDC  ................ 100mA
Operating Temp. ............................ -40F to +185F
Room Temp. Range ........................ +55F to +90F
Room Temp. Display Range .............. +35F to +99F
Thermostat Accuracy ................................ +/- 1F
Switching Capability A/C ..........................up to 24 VAC

(max. 2 AMPs)

THERMOSTAT INSTALLATION

Thermostat is very sensitive. 

HANDLE

WITH CARE AT ALL TIMES

.

Locate thermostat 48˝ to 54˝ above
floor on an 

INTERIOR

wall. Pick a dry

area where air circulation is good.

EXTERIOR

wall location must have a

3/4˝ spacer between thermostat and
exterior wall.

1. Be sure all electrical power has

been disconnected from the air
conditioner, furnace and the
power supply.

2. Do not install the thermostat

where there are unusual heating
conditions: such as direct
sunlight, heat producing
appliances (television, radio, wall
lamp, etc.) or a furnace or air
conditioner supply register.

3. 

ATTACHING THE WALL THERMOSTAT

.

Separate the thermostat body
from the sub-base by gently
squeezing the top and bottom,
connecting wiring per
requirements. Attach thermostat
sub-base to the wall at desired
mounting location.

THIS THERMOSTAT HAS BEEN DESIGNED TO OPERATE STANDARD AIR CONDITIONING UNITS IN CONJUNCTION WITH A RV FURNACE

.

COOL

FAN

OFF

HEAT

M

Display

System Switch

Temperature Set

Mode Set

7.5 VDC ANALOG A/C SYSTEMS (DOMETIC

®

)

THERMOSTAT

WIRE FROM FURNACE

WIRE FROM A

/

C

TERMINAL

# (

L

-

R

)

FUNCTION

FUNCTION

1

-

12vdc ground

4

7.5 vdc

3

+12vdc

5

Compressor

6

High Fan

7

Low Fan

8

Furnace Control

12 VDC ANALOG A/C SYSTEMS (RVP

®

)

THERMOSTAT

WIRE FROM FURNACE

WIRE FROM A

/

C

TERMINAL

# (

L

-

R

)

FUNCTION

FUNCTION

1

-12vdc ground

2

not used

not used

3 & 4

+12vdc

5

Compressor

6

High Fan

7

Low Fan

8

Furnace Control

SLIDE SWITCH

SCROLL ORDER OF

LEFT

RIGHT

DISPLAYED MODES

OPERATION

COOL OFF

HEAT FAN

Furnace Operation

HI

Furnace cycles to satisfy set point.

COOL OFF

HEAT FAN

Air Conditioner Operation

AU

Air conditioner automatically switches compressor and high and
low speed fan when cycling to satisfy set point.

HI

Air conditioner compressor and high speed fan cycle to satisfy
set point.

LO

Air conditioner compressor and low speed fan cycle to satisfy
set point.

COOL OFF

HEAT FAN

Fan Operation

HI

Air conditioner fan runs at high speed to circulate air.

LO

Air conditioner fan runs at low speed to circulate air.

COOL OFF

HEAT FAN

Off

OF

No operation occurs.

WIRING REQUIREMENTS FOR ATWOOD THERMOSTAT

FURNACE

12 VDC

SOURCE

     +

7.5V

HI F

AN

6

LO

W F

AN

7

COMPRESSOR

5

4

8

3
1

FURNACE

      +

Y

GH

GL

B

HI F

AN

6

LOW F

AN

7

COMPRESSOR

5

12 VDC

SOURCE

8

3

1

CONNECT

TO

3

WITH JUMPER

1

12VDC

Ground

3

+12VDC

2

NOT

USED

Screw Mounting Holes

4

RELAY

COM

*

5

A/C 

COM-

PRESSOR

6

A/C

HI

FAN

7

A/C

LOW 

FAN

8

TH FROM
FURNACE

*Note:  Move jumper to

positions 3 and 4 for RVP
Unit. Discard jumper for
Dometic

®

.

Reviews: