FLUSH MOUNTING
A detachable mounting bracket allows the unit to be mounted as a
flush installation supplied with the unit.
Mounting brackets attached to the surface where the alarm is to be
mounted with four screws, see instructions below.
To install the mounting bracket to the alarm place the alarm inside the
bracket and snap in place see diagram. To remove flush mounting
bracket pull legs away from body of detector.
1. Verify that there is a minimum of (C)1-
1/2” inches of free space behind
the wall.
2. Mark on the desired mounting surface a box approximately (A) 2-5/8
”
inch wide by (B) 3-5/8
” high and cutout.
3. Route power leads to the opening and connect wire to the detector
per the wiring diagrams.
4. Install the detector and excess wiring through the opening until
mounting flange is flush to the wall.