Functional   

When the Paging Receiver/PS-Micro mobile is placed in the rack, its batteries will be charged (if the switch in the battery 
compartment in the receiver/PS-micro mobile is set in the right position).  
 

4.1  Bleep while in rack 

Special for pagers a switch is built in the storage rack to decide if you want to  
receive calls or not when a pager is in the storage rack.  

 

By default the switch SW1 is set such that a pager will bleep when it receives  
a call while placed in the storage rack. 

 

4.2  No Bleep while in rack/Charge only 

This type of storage rack has the option to disable the pager to receive  
calls from the system. When SW1 is set In that situation the pager will not  
bleep when the system sent a call to that particular pager. 
 

 

 

Note:

   The internal switch SW1 in the storage rack, can be reached by  

              removing the bottom plate. When it is set to No-Bleep, the pager  
              will not receive any call 

– so it will not bleep  when called, 

             calls are 

not stored in the pager’s memory then. 

 
 

4.3  LED indications 

When a pager/PS-micro mobile is placed in the rack good positioning is indicated by the  
LED  

on top of the storage rack.  

 

When the LED illuminates bright it indicates good positioning of the mobile.  

 

To see the different positions of SW1 (Bleep or No-Bleep mode) the LED on the  
storage rack will illuminate with reduced intensity when s

et in “No-Bleep” mode. 

 

4.4  Reset Alarms (remote reset-absent) 

 

When a PS-Micro mobile is placed in the storage rack while the mobile is in alarm state,  
the alarm state of the PS-Micro mobile will be reset. This independent how is SW1 set. 

 

If the Alarm Central is programmed such that 

‘remote reset’ is enabled, the alarm state  

in the central is reset too. 

 

If a PS micro mobile is placed in the rack, the internal alarm-sensors are  
disabled, besides this the mobile goes to absent-state in the system. 

 

4.5  External Signalisation when in rack 

When a pager is placed in the rack a relays becomes active. The relays  
has 2 voltage free contacts, one Normal Open (NO)  and a Normal Closed (NC)  
contact which can be used for external signalisation if the rack contains a pager  
or not.  

 

This option can be used as a kind of external absent indicator. 

 

The electrical values are 12Vdc-1Adc 

 

Both pager receiver and a PS-Micro Mobile are detected. 

 

4.6  Power Supply 

The rack is powered from a 9-12 V power supply or car battery.  
Connect the output power connector of the adaptor to the socket 

2

  at the rear of storage rack.  

Connect the external power adaptor into a mains wall socket. 
The storage rack is now ready for operation. 
 

4.6.1 

Fuse 

The Single Storage rack is equipped with a fuse F1, 250mA, to prevent overload. 
The fuse is positioned inside the housing and can be reached by removing the bottom 
cover, unscrew the Printed board to reach it. 

 

 

   

Warning:

  

- Do not place the racks close to sources of heat, radiators or in direct  
  sunlight. 
- IPS B.V. recommends that all critical and stationary equipment be  
  connected to an Uninterrupted Power Supply. 

NC 

 

NO 

NC 

 

NO 

BLEEP 

NO BLEEP 

BLEEP 

NO BLEEP 

BLEEP 

NO BLEEP 

Summary of Contents for LBB6152/01

Page 1: ...Single storage rack Installation manual II_LBB615201_en_1817 LBB6152 01 Single storage rack for Paging receivers and PS micro Mobiles...

Page 2: ...5 3 1 Commercial items 5 4 Functional 6 4 1 Bleep while in rack 6 4 2 No Bleep while in rack Charge only 6 4 3 LED indications 6 4 4 Reset Alarms remote reset absent 6 4 5 External Signalisation when...

Page 3: ...go there 1 3 Disclaimer Atus is a brand name of International Pagerservices B V IPS IPS reserves the right to change data and or specification of any equipment or software mentioned in this publicati...

Page 4: ...sing out of any unauthorized modification of design Warning Use of substitute replacement parts which do not have the same specified characteristics may create shock fire or other hazards To maintain...

Page 5: ...outside the hazardous environment The single storage rack is default delivered without PSU The LBB6152 01 is compatible with its predecessor the LBB6152 00 and can be used in combination with all Atu...

Page 6: ...de 4 4 Reset Alarms remote reset absent When a PS Micro mobile is placed in the storage rack while the mobile is in alarm state the alarm state of the PS Micro mobile will be reset This independent ho...

Page 7: ...ile the receiver is in the rack When SW1 is in the Bleep position the volume of the bleep will not be changed when the pager is placed in the rack The design of the rack is such that it fits esthetica...

Page 8: ...S B V will not be held responsible for Charge racks that show abnormal use Charge racks that are offered for repair after the 1 year IW period The power supply Repairs that are made by a third party U...

Page 9: ...vices B V Willem de Haastraat 5 5421 TN Gemert The Netherlands http www atusbv com https pagerservices nl 2018 International Pagerservices B V All rights reserved Data subject to change without notice...

Reviews: