background image

* You can switch ON / OFF repeatedly by pressing the "DAT" switch.

* Short press the "FUN" switch to confirm the setting. Next is the setting for reset to initial setting.

7-12.Set backlight

 

BL

 

(Initial Setting: OFF

Turn the backlight ON / OFF.

  Turn on the backlight when using in a dark place. The backlight will brighten the screen and make it easier to see. 
* When the backlight is ON, it consumes a lot of battery power and shortens the usage time.
* You can switch ON / OFF repeatedly by pressing the "DAT" switch.

* Short press the "FUN" switch to confirm the setting. Next is the setting for polarity.

7-13.Set polarity

 

IN

 

(Initial Setting: OFF

When OFF, compression side is set to + and tension side is set to -, but when ON, compression side is set to -

  and tension side is set to +.

Comparator

 HI

Intermittent sound (fast)

Remove the load and press "RES" switch.

Comparator

 LO

Intermittent sound (slow)

Remove the load and press "RES" switch.

Switch operation

Short sound

* You can switch ON / OFF repeatedly by pressing the "DAT" switch.

* Short press the "FUN" switch to confirm the setting. Next is the setting for backlight.

* The following is a list of buzzer sounds.

Action 

Sound

The way to stop buzzer

Overload

Continuous sound

Remove the load and press "RES" switch.

7-11.Set buzzer

 

BP

 

(Initial Setting: ON)

Set whether to sound the buzzer or not.

 

The buzzer gives a warning during the main body operation or various settings.

 

When the buzzer sound is annoying, you can turn it off to silence the sound.

The display changes every time 

the "DAT" switch is pressed.

The display changes every time 

the "DAT" switch is pressed.

The display changes every time 

the "DAT" switch is pressed.

Summary of Contents for AD-FG Series

Page 1: ...Digital Force Gauge Operation Manual AD FG Series ATTONIC CO LTD Standard type ...

Page 2: ...arts according to this manual 1 10 Use the specified accessories appropriate bits and sockets Do not use any accessories or attachments not described in this manual In the following cases switch off the main body and disconnect the plug from the power supply When not used or charged When other danger is predictable 1 9 Check if there are any damaged parts Before use check it thoroughly for any dam...

Page 3: ...t apply large twisting forces lateral bending forces and forces that exceed a tolerance to the detection shaft otherwise the detector will be damaged 2 6 Do not use this gauge for any purpose other than measurement operation 2 3 Do not work in an unnatural working posture Keep proper footing and balance at all times 2 4 Do not be negligent in using this gauge and handle it with great caution When ...

Page 4: ... the screw more than 10mm it is possible that the internal board is broken and cause malfunction Battery fixing screws 2places Display DC IN Power Jack FUN Switch Detection shaft RES Switch Mounting screws for the main body M4 3places 3 Parts names 3 1 The name and application area of parts POW Switch I O Socket DAT Switch ANALOG Output Jack ...

Page 5: ...3 2 Attachments S 2 V type B S 3 Cone type S 4 Flat type S 6 Extension rod type S 1 V type A S 5 Hook type S 7 Double hook type ...

Page 6: ...ger IN AC100V 240V OUT DC9V Dimension About 187 208 with the shaft included L 80 W 42 H Usage time About 12 hours in continuous use Battery life Rechargeable more than 300 times depending on usage conditions Auto power off Power off after being left for 10 min Measurement without any time limit is also available Battery powered Rechargeable Ni MH Battery 1 2v 4cells 1650mAh Measurement unit Switch...

Page 7: ... this gauge firmly with a tool etc 5 3 Attachment installation Use the supplied attachments according to the measurement conditions If you cannot measure with the supplied attachments please contact us We also manufacture special attachments Do not use attachments from other suppliers They may cause a malfunction or injury Cautions 5 2 Mounting When the power is turned off the stored data N 〇〇〇 wi...

Page 8: ...are changed The display becomes 0 zero when RES switch is pressed Exit when the screen goes off Set other functions Compression test Tension test Long press the POW switch when the test is finished 6 Basic flow of usage Power ON POW switch ON Set measurement mode Set measurement unit ...

Page 9: ...switch The setting is complete When measurement screen appears 7 1 Set measurement mode Initial Setting TRACK You can switch the measurement mode Switch between TRACK mode and PEAK mode by pressing the DAT switch The one with a black background is the one selected TRACK The torque value applied to the detector is displayed as it is It is used to view measurements that change constantly 7 Function ...

Page 10: ... of side instead of an absolute value A short intermittent sound will be heard if the HI setting value side is exceeded and a long one if the LO setting value side is exceeded After that even if the HI peak value is exceeded a long 〇 TRACK PEAK Mode You can change the HI side setting value of the comparator A comparator is a comparison with a set value For example if you set the point of high valu...

Page 11: ...creen update rate The setting value should be entered as the value of side instead of a absolute value A short intermittent sound will be heard if the HI setting value side is exceeded and a long one if the LO setting value side is exceeded After that even if the HI peak value is exceeded there is still a long intermittent sound A long intermittent sound will be heard if the LO setting value side ...

Page 12: ...tch to confirm the setting Next is the setting for the minimum digit display 7 10 Set the minimum digit display MD Initial Setting ON For example when measuring with the detection shaft facing up the values are reversed and difficult to read but by turning on this setting the values can be read as they are You can switch ON OFF repeatedly by pressing the DAT switch Short press the FUN switch to co...

Page 13: ...ide is set to and tension side is set to Comparator HI Intermittent sound fast Remove the load and press RES switch Comparator LO Intermittent sound slow Remove the load and press RES switch Switch operation Short sound You can switch ON OFF repeatedly by pressing the DAT switch Short press the FUN switch to confirm the setting Next is the setting for backlight The following is a list of buzzer so...

Page 14: ...en Printer Output Setting is ON PEAK or PP mode is chosen the letter PO is showed at the lower left part of display This letter PO is not shown when TRACK mode is chosen When you push Reset switch at this moment the main unit will not be controlled while few seconds until the display is reset because the main unit is in the mode for searching printer Please choose this setting OFF when you do not ...

Page 15: ...ayed in the upper right corner of the screen If MO is not displayed long press the DAT switch again until you hear a beep Please note that it is set longer so that the measurement mode will not be switched due to a malfunction during measurement To complete the setting long press the FUN switch again until you hear a beep 8 Checking method on history data and function description Measure in peak m...

Page 16: ...PC etc in a batch For example if the number of stored data is 20 N 〇〇〇 at the top center of the screen will be N 020 The value of 〇〇〇 in N 〇〇〇 cannot be changed The value of 〇〇〇 in N 〇〇〇 cannot be changed The display changes every time the DAT switch is pressed Press the POW switch to transfer the data This screen appears when the data transfer is finished To all clear function FUN switch The disp...

Page 17: ...ep The AV display in the upper right corner of the screen disappears and the gauge becomes measurement 9 1 MAX MIN AVE values 9 Checking method on MAX MIN AVE values and function description You can check the MAX MIN AVE values of all stored data Check MAX MIN AVE values Short press the DAT switch in peak mode PE to check MAX MIN AVE values When the display shifts to the check screen for MAX MIN A...

Page 18: ...ay value of side is greater than or equal to the setting value in PP mode ON when it is overloaded Digimatic CLK Digimatic DAT Digimatic RDY RES switch ON when the value is greater than or equal to comparator HI ON when the display value of side is greater than or equal to the setting value in PP mode ON when it is OK ON when the value is less than or equal to comparator LO Function Power input It...

Page 19: ...ection to external devices Do not short circuit It may cause a malfunction Do not apply voltage from outside 12 Digimatic data transmission connection Printer DP 1VA The cable is available as an option The measured values can be printed out by Mitutoyo s Digimatic Mini Processor DP 1VA External devices F G shielded wire Digital force gauge Dedicated cable Mitutoyo Co Ltd Digimatic Mini Processor D...

Page 20: ...IPPED ON POWER_OFF Auto power off ON permission OFF none POWER_OFF ON AUTO_CLEAR ALL CLEAR ON permission OFF none AUTO_CLEAR ON MIN_DIGIT Minimum digit display ON permission OFF none MIN_DIGIT OFF BUZZ Buzzer permission ON permission OFF none BUZZ OFF BACK_LIGHT Backlight permission ON permission OFF none BACK_LIGHT ON GAIN_INVERT Plus minus inversion ON permission OFF none GAIN_INVERT OFF INIT_VA...

Reviews: