ATTO Technology UL3D Installation And Operation Manual Download Page 18

15 ATTO Technology ExpressPCI Ultra/WIDE SCSI Host Adapters Installation and Operation Manual

4 Maximizing Performance with ExpressPCI HBA

If you are getting less performance than you expect, there are several things you can do such as making 
sure you are using the latest ATTO driver, setting the registry entry for large block transfers, using ATTO 
ExpressRAID for setting up RAID groups, increasing transfer size, and analyzing your system’s I/Os. 

While the factory settings on your ExpressPCI 
host adapter should provide excellent 
performance for a wide range of applications, you 
may improve performance by modifying some of 
the system factors which affect your ExpressPCI 
host adapter. 
For example, the ATTO driver can transfer well 
over a megabyte with one SCSI command. 

NOTE

You must use an ATTO driver when using ATTO 

ExpressRAID software.

Use the latest ATTO driver

Determine which drive is currently in use, then 
install the latest ATTO driver found at 
www.attotech.com. 

Windows NT

1

Open 

My Computer

2

Open 

Control Panel

3

Open 

SCSI Adapters

4

Examine  the 

Driver tab

 for your SCSI 

adapter. If the driver is not 

express.sys

install the 

express.sys

 driver.

5

Either remove the previously-installed 
driver or disable it using the Devices applet. 
If the system has a built in Symbios or LSI 
adapter, do not disable the driver for that 
adapter.

Windows 2000 and XP

1

Using the 

Device Manager, 

select 

SCSI & 

RAID Controllers

2

Examine  the 

Driver tab

 for your SCSI 

adapter. If the driver is not 

express.sys

install the 

express.sys

 driver.

3

Either remove the previously-installed 
driver or disable it using the Devices applet. 
If the system has a built in Symbios or LSI 
adapter, do not disable the driver for that 
adapter.

Set registry for large block transfers

If your application requires large block transfers, 
set the registry entry correctly for the 
MaximumSGList keyword. Several files supplied 
with the device driver download package can set 
this value to any one of the following sizes: 64Kb, 
128KB, 256Kb, 512KB, 1MB and NT default 
(64KB). The files are ASCII text files and can be 
viewed with any suitable editor. The files also 
explain the registry setting and how to change the 
setting.

The ExpressPCI adapter can have a maximum 
transfer size from 64KB to 1MB. If the registry 
value is set to a number higher than 0xff, the 
driver will reduce the setting to 0xff. The driver 
installation process will set the default value to 
0xff.

Set up RAID groups with ATTO 
ExpressRAID

Instead of using the RAID functionality built into 
Windows OS, use the ATTO ExpressRAID 
software for the most efficient performance. 

ATTO ExpressRAID requires one less level of 
driver through which commands must pass and 
fewer commands are required to pass through the 
driver hierarchy.

Other advantages of ATTO ExpressRAID 
striping: 

You can boot your system off striped drives

Stripe sets created with ExpressRAID are 

recognizable by DOS and Windows

You can stripe removable-media drives with 

ExpressRAID. 

If you have purchased the striping option, 
additional information about ExpressRAID is 

Summary of Contents for UL3D

Page 1: ...Channel Ultra3 UL3S Single Channel Ultra3 66 MHz UL3S 66 2003 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may b...

Page 2: ......

Page 3: ...ce Drivers 11 Windows Server 2003 Windows 2000 XP Windows NT Installation Re flashing Firmware in Windows Linux and Sun Solaris Driver Installation Updating Drivers and Re flashing Firmware in Mac OS...

Page 4: ...ured according to your system ATTO provides a variety of configuration tools if you need to alter the host adapter s configuration See the ATTO ExpressPCI Utilities manual for additional information F...

Page 5: ...4 bit 66 Mhz 532 MB sec Maximum SCSI transfer rate Synchronous data rate UL3D UL3D 66 60 MB sec per channel Ultra3 mode Asynchronous data rate 12 MB sec per channel all models SCSI Interface SCSI 1 SC...

Page 6: ...and the SCSI Consortium www iol unh edu consortium Term Definition ANSI American National Standards Institute auto negotiation hardware senses and automatically responds depending on configuration BER...

Page 7: ...t of the parts of a computer system or network and their interconnections transceiver a transmitter receiver module transfer rate the rate at which bytes or bits are transferred as in megabytes or gig...

Page 8: ...ers J1 and J2 when installed vertically ensure ATTO ExpressPCI 64 bit cards work correctly in 32 bit mode in all 32 bit PCI slots These jumpers do not force the ExpressPCI card to operate in 32 bit mo...

Page 9: ...PCI UL3D UL3D 66 adapter 64 32 Bit PCI 2 2 Compliant Connector 68 pin VHDCI Connector 68 pin Connector Ultra3 SCSI Processor Channel 2 68 pin VHDCI Connector Channel 1 68 pin VHDCI Connector 64 32 Bit...

Page 10: ...ossible to ensure higher signal quality and performance Examples The SCSI specification limits total bus cable length for Single Ended SCSI in a non UltraSCSI environment to 3 meters combined length o...

Page 11: ...ded Low Voltage Differential and Differential SCSI busses use different types of terminators that should not be mixed Single Ended and LVD signaling The ExpressPCI Ultra3 SCSI host adapter supports tw...

Page 12: ...l occur without proper termination Using internal and external connectors on UL3D UL3D 66 The UL3D UL3D 66 has two connectors on each SCSI bus an internal connector and an external connector Devices c...

Page 13: ...10 Cables and termination...

Page 14: ...pted Windows 2000 The Found New Hardware Wizard will appear proceed through the wizard defaults and insert the ExpressPCI Installation disk when prompted 10 When adapter installation is complete the F...

Page 15: ...ave Disk 7 Insert your ExpressPCI Installation Disk 8 Enter the path for it under Copy manufacturer s files from 9 Click OK 10 A list of ExpressPCI adapters will be displayed Select your adapter and c...

Page 16: ...n To re flash the firmware to the latest version 1 Obtain the latest firmware from the ATTO web site www attotech com 2 Extract the firmware to a floppy disk by executing the self extracting file 3 Re...

Page 17: ...firmware to the latest version 1 Obtain the latest firmware and updater program from the ATTO web site www attotech com and download to your host 2 Create a folder or drive where you want the program...

Page 18: ...e the Driver tab for your SCSI adapter If the driver is not express sys install the express sys driver 3 Either remove the previously installed driver or disable it using the Devices applet If the sys...

Page 19: ...to use over lapped I O using the FILE_FLAG_OVERLAPPED option with the CreateFile call Overlapped I O allows the application to send many commands to the device at once The ATTO Disk Benchmark program...

Page 20: ...Verity that all devices and busses are properly terminated See Chapter 3 1 for more information 9 Verify that all devices attached to the ATTO ExpressPCI SCSI adapter have unique SCSI IDs ATTO Express...

Page 21: ...18 Troubleshooting...

Page 22: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the...

Page 23: ...SCSI host adapter ExpressRAID software and appropriate cable s Add KIT suffix to host adapter product code i e EPCI UL3D KIT Specific features Single Channel ExpressPCI Ultra 320 Express PCI Ultra 3 E...

Page 24: ...s FC 3342 FC 3322 FC 3321 FC 3300 FC 3305 Fibre Channel ports 4 2 2 1 1 Optical interface SW LC SFP SW LC SFP SW LC SFF Fixed SW LC Copper interface HSSDC Max transfer rate 400MB sec per channel 400 M...

Page 25: ...ern Standard Time 8 00 a m to 8 00 p m or by e mail and web site 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice 716 691 9353 fax http www attotech...

Reviews: