ATTO Technology ATTO ExpressPCI Ultra/WIDE SCS Installation And Operation Manual Download Page 12

9 ATTO Technology ExpressPCI Ultra/WIDE SCSI Host Adapters Installation and Operation Manual

To set up cabling and termination:

1

Determine whether your ATTO Express PCI 
adapter is a single channel or dual channel 
model. One external connector indicates a 
single channel host adapter; two external 
connectors indicate a dual channel host 
adapter.

2

Determine if SCSI devices will be installed 
internally or externally. 

Total bus cable length,

varies by host adapter and 

type of attached devices. Refer to Exhibit 3.1-1 
for details on maximum cable length.

If you combine Wide 16-bit and Narrow 8-bit 
devices on the same connector, 

connect the 

Wide devices first (closest to the connector). 

Exhibit 3.1-4

Please refer to the documentation for 

your SCSI devices to determine they are Wide or Narrow.

3

Determine which terminator to use

Use an LVD terminator if you are only using LVD 
devices. 

Although you can use a Single-Ended 

terminator, all devices will be limited to Ultra 
SCSI speeds. Single-Ended devices require a 
Single-Ended terminator. If you use an LVD 
terminator with Single-Ended devices, the system 
may hang or devices may not be seen on the SCSI 
bus. Some termination manufacturers provide 
automatically sensing terminators.

External terminators should be attached to the 
last external device in the SCSI chain. 

Don’t use 

any other termination on the external SCSI chain. 
The last device on an internal SCSI chain should 
also be terminated. This can be done in several 
ways. Many Single-Ended Ultra SCSI and earlier 

devices provide a jumper setting for applying 
termination: place a jumper over the pins 
designated for termination on the last device on 
the internal cable. Check with your drive 
manufacturer if you are not sure which pins to 
use. 

Wide (16-bit) and Narrow (8-bit) devices 

can be 

connected together on the same connector of the 
host adapter card, but wide devices must be 
attached first, followed by narrow devices. 

To terminate the SCSI bus, the cable or adapter 
used to convert from a wide (68-pin) connector to 
a narrow (50-pin) connector provides partial 
termination, allowing upper 8-bits (or byte) of the 
wide SCSI bus to be properly terminated. A 
narrow terminator should be used on the last 
narrow device to terminate the rest of the SCSI 
bus. A SCSI bus without partial termination 
between the wide and narrow devices may at first 
appear to work correctly, but occasional I/O errors 
will occur without proper termination.

NOTE If you use both internal and external connectors 
and mix Single-Ended and LVD devices on the same bus, 
even if using different connectors, the host adapter card 
will operate with Single-Ended signaling at UltraSCSI 
speeds.

Automatic termination: 

when both internal and 

external connectors are used, the host adapter card 
detects the presence of devices and turns off 
termination. If devices are removed from one 
connector of the card, the host adapter will 
automatically detect the change and enable its 
own termination.

Software controlled termination: 

You may have 

to override the host adapter’s automatic 
termination if only narrow devices are attached to 
one connector and wide devices are attached to 
the other connector on the same bus. The host 
adapter must supply partial termination to the 
upper 8-bits (byte), but it will not do so 
automatically. Please refer to your ExpressPCI 
Utilities manual to set the host adapter’s 
termination to Upper Byte.

Internal 

Connection

External 

Connection

Termination 

Selection

Wide Device

Wide Device

None

not used

Wide Device

Full

Wide Device

not used

Full

Narrow Device

not used

Full

not used

Narrow Device

Full

Narrow Device

Wide Device

Upper

Wide Device

Narrow Device

Upper

Narrow Device

Narrow Device

Upper

Summary of Contents for ATTO ExpressPCI Ultra/WIDE SCS

Page 1: ...WIDE ExpressPCI DC Dual Channel Single Ended Ultra WIDE 2003 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may be...

Page 2: ......

Page 3: ...dows Server 2003 Windows 2000 XP Windows NT Installation Re flashing Firmware in Windows Linux and Sun Solaris Driver Installation Updating Drivers and Re flashing Firmware in Mac OS X Updating Driver...

Page 4: ...these tools Features Automatic termination Advanced Data Streaming ADS Technology RAID ready Embedded RISC I O processor Flash ROM BIOS for easy field upgrades PCI 2 1 Compliant Includes Mac OS and PC...

Page 5: ...2 Features benefits...

Page 6: ...tion is available through the ATTO Technology website www attotech com and the SCSI Consortium www iol unh edu consortium Term Definition ANSI American National Standards Institute auto negotiation ha...

Page 7: ...elligent devices including hard disks floppy disks CD ROM printers scanners etc topology logical layout of the parts of a computer system or network and their interconnections transceiver a transmitte...

Page 8: ...adapter After turning off the computer leave the power cable plugged into a grounded outlet to discharge static electricity 3 Open the computer case 4 Install the ATTO ExpressPCI host adapter in any...

Page 9: ...CI Connector Channel 1 68 pin VHDCI Connector Channel 1 68 pin Connector Channel 2 68 pin Connector 68 pin Internal 16 bit P Cable Connector Dedicated 3rd Generation RISC Based UltraSCSI Processor 50...

Page 10: ...1 meter of cabling to connect all of its drives the distance from the tower to the host must be 5 meters NOTE UltraSCSI is very sensitive to SCSI bus noise cable distances and the number of devices c...

Page 11: ...SCSI buses use different types of terminators that should not be mixed Single Ended ATTO ExpressPCI PSC DC incorporates advanced termination circuitry to automatically configure its own termination Ex...

Page 12: ...use Wide 16 bit and Narrow 8 bit devices can be connected together on the same connector of the host adapter card but wide devices must be attached first followed by narrow devices To terminate the SC...

Page 13: ...and many SCSI devices are also able to supply termination power SCSI signal quality particularly with long or marginal quality cables may be improved if the device supplies the termination power Cont...

Page 14: ...pted Windows 2000 The Found New Hardware Wizard will appear proceed through the wizard defaults and insert the ExpressPCI Installation disk when prompted 10 When adapter installation is complete the F...

Page 15: ...ave Disk 7 Insert your ExpressPCI Installation Disk 8 Enter the path for it under Copy manufacturer s files from 9 Click OK 10 A list of ExpressPCI adapters will be displayed Select your adapter and c...

Page 16: ...Windows copied the driver to the hard disk Re flashing Firmware in Windows ATTO typically releases adapter firmware and drivers simultaneously We recommend that both the firmware and drivers be update...

Page 17: ...versions and attempt to flash Instructions for using this utility are provided as part of the download process Updating Drivers and Re flashing Firmware in Mac OS 9 To re flash the firmware to the la...

Page 18: ...ine the Driver tab for your SCSI adapter If the driver is not express sys install the express sys driver 3 Either remove the previously installed driver or disable it using the Devices applet If the s...

Page 19: ...to use over lapped I O using the FILE_FLAG_OVERLAPPED option with the CreateFile call Overlapped I O allows the application to send many commands to the device at once The ATTO Disk Benchmark program...

Page 20: ...9 Verity that all devices and busses are properly terminated See Chapter 3 1 for more information 9 Verify that all devices attached to the ATTO ExpressPCI SCSI adapter have unique SCSI IDs ATTO Expre...

Page 21: ...18 Troubleshooting...

Page 22: ...receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian standards This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la...

Page 23: ...host adapter ExpressRAID software and appropriate cable s Add KIT suffix to host adapter product code i e EPCI UL3D KIT Specific features Single Channel ExpressPCI Ultra 320 Express PCI Ultra 3 Expre...

Page 24: ...FC 3305 Fibre Channel ports 1 1 1 2 1 Optical interface Fixed SW SC Fixed SW LC Fixed SW LC Copper interface HSSDC HSSDC Max transfer rate 200 MB sec full duplex 200 MB sec full duplex 400 MB sec ful...

Page 25: ...ern Standard Time 8 00 a m to 8 00 p m or by e mail and web site 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice 716 691 9353 fax http www attotech...

Reviews: