attika ElectronicAIR User Manual Download Page 4

18 - GB

GB

NB: 

Whenever the batteries are changed in the receiver, synchronisation must be repeated.

*If you did not manage to synchronise the remote control and the receiver during this time, remove the batteries and then put 
them back. You can then repeat the synchronisation process.

SYNCHRONISATION OF THE REMOTE CONTROL AND RECEIVER

The remote control must now be synchronised using the wood-burning stove receiver. Procedure to synchronise the remote control 
and receiver: 

1. 

Insert batteries in the receiver.

2. 

The LED light in the front of the wood-burning stove should flash yellow and then light green. This means that the damper 

is operating a start-up reference test. You may also hear a ‘click’ sound, which is completely normal. This process may take 
up to two minutes.

3. 

After the test is finished, 

the LED light will flash red for 20 seconds

. During this time, the remote control and receiver are 

synchronised*. First, press the ‘up’ button and then press the ‘down’ button. 

4. 

The LED light will briefly light green when the synchronisation is complete and then go out.

INSERTING BATTERIES IN THE REMOTE CONTROL

1. 

First, insert new batteries in the remote control.

2. 

The remote control must be in the manual setting for the remote control and the receiver to synchronise. If the remote 

control is in the automatic setting, set it to manual by briefly pushing the ‘up’ and ‘down’ buttons at the same time.

Manual setting

Automatic setting

Down

Up

Summary of Contents for ElectronicAIR

Page 1: ...DK 1 DK BRUGERVEJLEDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUKERVEILEDNING BRUKSANVISNING K YTT OHJE GEBRUIKERHANDLEIDING...

Page 2: ...ctronicAIR 17 Start up 17 Inserting batteries in the remote control 18 Synchronisation of the remote control and receiver 18 Setting the remote control 19 Use of wood burning stove with ElectronicAIR...

Page 3: ...stantly communicate with the receiver and remote control Based on this communication the damper opens or closes automatically to ensure the optimal combustion during the start up and continuous burnin...

Page 4: ...that the damper is operating a start up reference test You may also hear a click sound which is completely normal This process may take up to two minutes 3 After the test is finished the LED light wil...

Page 5: ...Settings are saved automatically SETTING THE REMOTE CONTROL The remote control can be set to display the time temperature etc To enter the manual setting menu press the up button and down button at th...

Page 6: ...ctivate the child lock Menu 6 Settings for type of fuel 00 wood or 01 coal It is very important that this setting is set to 00 wood 00 Setting for wood 01 Setting for coal When you have finished with...

Page 7: ...n for approximately five minutes Next close the door 4 Once there is a good layer of embers place two logs on the fire 5 ElectronicAIR regulates the actual combustion air during burning USE OF WOOD BU...

Page 8: ...e receiver Replace the batteries in the receiver LED light is constantly lit red Fault The receiver has no power In this situation the damper opens completely and stays open until the batteries are re...

Reviews: