1.7 – Factory Reset
The unD6IO has a factory reset option. Using it will reset all the devices parameters back to their factory defaults including
all the Dante settings such as device name, channel names as well as the device settings such as input select. The devices
IP address mode is also reset back to getting a dynamic IP.
Access to the factory reset button is through a small circular hole on the
underside of the unit, next to the ventilation cutouts.
To use the factory reset, insert a small screwdriver or paperclip into the
hole to activate the factory reset switch. There should be a noticeable
“click” when it’s activated. Hold the switch in for 5 to 10 seconds then
release. If the factory reset was successful, the unit will actually reset