background image

 

 

 

User Manual 

 Attero Tech, LLC 

1315 Directors Row, Suite 107, Ft Wayne, IN 46808 

Phone 260-496-9668 • Fax 260-496-9879 

www.atterotech.com

 

 

614-00040 

 

 

 

 

 

 

2x2 AES67 Interface 

 

 

 

User Manual 

 

Date 03/21/18 

 

Revision 01_b 

 
 

Summary of Contents for unAIO2X2+

Page 1: ...User Manual Attero Tech LLC 1315 Directors Row Suite 107 Ft Wayne IN 46808 Phone 260 496 9668 Fax 260 496 9879 www atterotech com 614 00040 unAIO2X2 2x2 AES67 Interface User Manual Date 03 21 18 Revis...

Page 2: ...outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories spe...

Page 3: ...warranty as outlined above NEITHER ATTERO TECH LLC NOR ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT SHALL BE LIABLE FOR ANY INDIRECT SPECIAL PUNITIVE CONSEQUENTIAL OR INCIDENTAL DAM...

Page 4: ...Connections 1 2 3 1 Balanced Output to a Balanced Input 1 2 3 2 Balanced Output to an Unbalanced Input 1 2 3 3 Unbalanced Output to an Balanced Input 2 3 Device Configuration 3 3 1 IP Address Setup 3...

Page 5: ...option is particularly useful if the unAIO2X2 is mounted in a remote location where access to a mains outlet is limited or indeed nonexistent The unit comes in a small form factor with integrated mou...

Page 6: ...art only 4 Ethernet interface connector and indicators 5 2 x Balanced line audio inputs 6 2 x Balanced line audio outputs Note The unAIO2X2 has a label on one of the mounting flanges that shows the MA...

Page 7: ...onnected requires in order to find how to connect it correctly see Hardware Connections section 2 3 for further details When powering using PoE o Attach the network port to a spare PoE enabled port on...

Page 8: ...three LED s are SYS SYNC and ERROR and the color of each LED has different meanings The tables below show the combination and what each combination means Color Description Red System booting Orange E...

Page 9: ...hieve the best audio performance throughout the system 2 3 1 Balanced Output to a Balanced Input 3 Wire Cable Pin 1 Pin 2 GND Balanced Output Terminal Block Plug Pin 3 1 2 3 XLR M 3 Wire Cable Sleeve...

Page 10: ...age 2 614 00040 Rev 01 2 3 3 Unbalanced Output to an Balanced Input Balanced Input Terminal Block Plug 2 Wire Cable Sleeve Tip TS Plug GND Balanced Input Terminal Block Plug 2 Wire Cable Sleeve Tip RC...

Page 11: ...gure IP addresses will not allow a unAIO2X2 device to correctly authenticate in the unIFY Control Panel software The input and output channels won t be visible and routing of audio to and from the unA...

Page 12: ...stream data will be removed The network settings will also be reset so the device will return to retrieving an IP address dynamically The power up defaults for the audio settings are also cleared For...

Page 13: ...22 Class A and EN55024 Class A and RoHS requirements The unit shall be the Attero Tech unAIO2x2 I O Interface 4 1 Device Specifications Audio Network Physical Level Standard Ethernet Connector Single...

Page 14: ...ttero Tech LLC 2018 Page A 1 614 00040 Rev 01 APPENDIX A Reference Documents The following table lists the relevant reference documents Document Title Location unIFY 3rd Party Software API Registered...

Page 15: ...Released Revision History Revision Date Author Description of change 00_a 08 08 17 CNL Initial Draft 00_b 11 1 2017 AJB Corrected grammar errors 00_c 11 13 17 CNL Changed Front back images to that of...

Reviews: