background image

Copyright information

Description of common icons

Essential knowledge for users

Safety precautions 

Disclaimer

WARNING

WARNING

Warning

Misuse of this product may lead to serious injury or death to the user.

Caution

Misuse of this product may lead to serious injury to the user or material damage to the object involved.

The design of this product (including internal software) and its accessories is under the protection of relevant state-laws.Any 
violation of the relevant rights of our company will be subject to legal sanctions. Users shall consciously abide by the relevant state 
laws when using this product.

Thank you for using our products. Before using the product, please read this manual carefully and pay attention to the relevant 
warnings and cautions mentioned in this manual.

Users are required to have basic knowledge of common sense and electrical operations before using the product. Minors shall 
use the product under the guidance of a professional or guardian.

[Caution]:To avoid damaging the equipment and keep the safety of the operational environment,please read this manual 
carefully and keep it well so that you may read it atanytime when necessary.

To avoid electric shock or injury to the human body or fire hazard,the following basic rules must be observed when using the 
equipment.In order to ensure personal safety,only parts and accessories approved or recommended by the original factory 
canbe used,otherwise serious consequences may occur!

When using this product, the soldering pencil/soldering tip, with the temperature up to 150-480

, may cause burns to the 

user or cause a fire due to improper application.
So Users shall strictly observe the following rules:

●  

Keep this product away from flammable materials.

●  

Keep the product out of children's reach.

●  

Do not use this product if you are inexperienced or have no sufficient necessary knowledge without the guidance of 

related personnel.

●  

Do not use this product under wet environment or with wet hands to avoid electric shock.

●  

Do not modify this product and its accessories without authorization.

●  

Please turn off the power when replacing parts and iron tips, and not resume the use until the equipment is completely 

cooled down.

●  

Please use the accessories from the original factory When replacing the product parts.

●  

Make sure to turn off the power switch when the equipment is temporarily stopped or out of use.

●  

To ensure the normal operation of this product’s ESD function,only three-core power cord shall be used as the host 

connectingline.

●  

Smoke will be generated during the soldering operations. So please pay attention to the smoke evacuation.

●  

Do not play or do other similar dangerous actions during using this equipment, because it can easily lead to injury to 

others or yourself.

●  

Do not use this product for purposes other than soldering.

●  

Do not modify this product and accessories, otherwise the original warranty will be invalidated or damage may occur to 

the product.

●  

When plugging and unplugging the power cord and handle plug, please hold the plug body and do not pull the cord.

●  

Do not hit the product or its accessories too hard during the operation, otherwise damage may occur to the product.

We will take no responsibility for any personal injury or property damage caused by reasons other than the product quality 
problem, which may include force majeure (natural disasters,etc.) or personal behavior during the operation of this product. 
This manual is organized, compiled and released by SHENZHEN ATTEN TECHNOLOGY CO.,LTD. according to the latest 
product features. We will not responsible for further notice of the subsequent improvement of the product and this Manual.

Summary of Contents for GT-6150

Page 1: ...GT 6200 GT 6150 User Manual GT compatible...

Page 2: ......

Page 3: ...Technical parameters 7 Description of working interface 8 Operations of temperature setup 10 Quick call the related parameters at certain temperature 11 Opening and close of GT 6200 channels 12 Parame...

Page 4: ...le materials Keep the product out of children s reach Do not use this product if you are inexperienced or have no sufficient necessary knowledge without the guidance of related personnel Do not use th...

Page 5: ...ertificate of qualification Power cord Operation manual 1 GT 6150 host 1 1 1 1 1 1 1 1 1 Certificate of qualification 3 5mm grounding receptacle GT 6200 GT 6150 product manual GT compatible GT Y130 ap...

Page 6: ...0 applicable to precision soldering occasion GT Y130 applicable to conventional soldering occasion Combo D Combo E Combo F Combo G GT Y050 applicable to precision soldering occasion GT Y150 applicable...

Page 7: ...tool channel 1 Setup menu switch key of the Interface for the soldering tool channel 1 Confirm key Menu key Up arrow key minus key Rapid temperature key 2 System setup menu switch key Rapid temperatu...

Page 8: ...nection steps for the whole equipment 6 Note To avoid the damage to the host do not forget to turn off the power when inserting the plug into or removing the plug from the soldering tools 1 1 2 2 1 2...

Page 9: ...e which can be called quickly 240x160 Dots white letters on blue Temperature 0 40 Relative humidity 80 Temperature 20 80 Relative humidity 80 Approximately 4kg 315 L 252 W 127 H mm English Chinese Pow...

Page 10: ...s abnormal code Status display area of channel 2 display power bar product working status abnormal code Actual temperature display area of channel 2 display of the indicative description of abnormal w...

Page 11: ...er the screen display System verion for 3 seconds Status display area of channel 1 display power bar product working status abnormal code Channel 1 rapid temperature 3 Fixed temperature icon display S...

Page 12: ...eds to be configured GT 6150 is not equipped with such channel Press UP arrow key to increase the temperature Press DOWN arrow key to decrease the temperature 8 50 50 c o GT Y050 200 300 400 00 50 50...

Page 13: ...ey to quickly call the set value at 200 Short press the 2 key to quickly call the set value at 300 Likely short press the 3 key to quickly call the set value at 400 Note Rapid temperature value can be...

Page 14: ...d close of GT 6200 channels 12 Long press 1 key to open or close channel 1 Long press 3 key to open or close channel 2 50 200 50 c o GT Y050 200 300 400 GT Y050 8 200 50 c o 200 300 400 GT Y050 GT Y05...

Page 15: ...to return to the main interface If there is no password protection or after the correct password is entered it will jump to the System Parameter setup interface At this time the system parameters can...

Page 16: ...t to the factory settings Exit Press to return to the main interface Used to set the system Language EN English CN Chinese The factory fault is English Total items of parameter setup menu of the host...

Page 17: ...the Parameter setup of the channels for the handle to carry out lockup operation on the whole equipment for welding processcontrol The factory default mode OFF When the system is under the password s...

Page 18: ...s After clicking the State as delivered key all the system setup parameters and channel parameters will be resumed to the factory default settings Note This is only applied to those parameters corresp...

Page 19: ...Temp3 Available for users to quickly call the set temperature 3 Fix Temp After this mode is activated the output temperature is locked at this set temperature value Temp UL the highest temperature tha...

Page 20: ...e temperature compensation value to 15 27 F to compensate the error of the output temperature When the handle is under the standby mode the maintaining temperature is 150 C 302 F the lowest standby te...

Page 21: ...will not enter into the dormancy state if the standby mode is not activated The factory default is OFF A total of 3 sets of temperature data are available for users to quickly call subject to the Tem...

Page 22: ...The configurable minimum temperature is 150 C 302 F The configurable maximum temperature of the Temperature lower limit shall be less than the Temperature upper limit value The factory default value...

Page 23: ...protective ground wire of the power line After the 3 5mm plug is inserted the ground wire of the soldering tool handle is connected to the 3 pins of the 3 5mm plug When the 3 5mm plug is connected to...

Page 24: ...he soldering head temperature is too high please cool the iron head and then restart the equipment 1 In case the handle is not compatible with this equipment please replace it with the handle produced...

Page 25: ...e free of charge For those product beyond the warranty period we provide life long maintenance services For those product damaged due to users improper application and unauthorized changes to the prod...

Page 26: ...uminum Press plate Interface panel Panel Interface board PCB Self adhesive foot pad Transformer Bottom shell Power board PCB Public seat Fuse Power cable Right decorative plate Left decorative plate T...

Page 27: ...within the guarantee period we will response for the maintenance free of charge on presentation of this card and the receipt We will repair and return the repaired equipment to the customer within 2 w...

Page 28: ...right Reserved MADE IN CHINA CBN029642 A Soldering iron Soldering station Hot air rework station Multi function maintenance system Regulated DC power supply Switching DC power supply Programmable powe...

Reviews:

Related manuals for GT-6150