ATTACK 

OT80 TERMOSTAT

MANUAL

EN

ATTACK 

OT80 TERMOSTAT

NÁVOD NA POUŽITIE

SK

SK/EN 2/2022

Summary of Contents for OT80

Page 1: ...ATTACK OT80 TERMOSTAT MANUAL EN ATTACK OT80 TERMOSTAT N VOD NA POU ITIE SK SK EN 2 2022...

Page 2: ...OD 6 2 1 PREH AD 6 2 2 PRV TARTOVANIE 6 3 ROZHRANIE 7 3 1 DISPLEJ 7 3 2 IKONY 8 3 3 GOMB K A KONTEXTOV TLA IDL 9 3 4 PREH AD MENU 9 4 RE IM STAV A PROGRAM 12 4 1 PRAVA STAVU APROGRAMU 12 4 2 STAVV ZNA...

Page 3: ...STAVENIE ECONOMY 17 6 3 5 ASOV PL NOVANIE 17 6 3 6 ANTI ZAMRAZOV FUNKCIA 17 6 3 7 PLNENIE VODOU 17 6 3 8 NASTAVENIE PARAMETROV 17 6 3 9 NASTAVENIE VYKON GRAFOV 19 6 4 V EOBECN NASTAVENIA 20 6 4 1 JAZY...

Page 4: ...mne a dokonca nebezpe n V robca nezodpoved za kody na u och zvierat ch alebo veciach ak s sp soben chybami v in tal cii regul cii a dr be a nevhodn m pou van m zariadenia Nerozoberajte asti zariadenie...

Page 5: ...iesto pre in tal ciu aby ste zaru ili spr vnu detekciu teploty v miestnosti Zariadenie sa odpor a in talova pri cca 150 cm v ke od podlahy mimo dver okien alebo zdrojov tepla ktor by mohli ovplyvni me...

Page 6: ...tla idlo gomb k ierno biely displej s podsvieten m Prav tla idlo av tla idlo obr zok 3 2 2 PRV SPUSTENIE Pozn mka OT80 komunikuje a je nap jan cez spojenie OT s kotlom Ke je kotol nap jan za ne praco...

Page 7: ...TING SETTINGS sekcia PARAM SETTINGS V pr klade zobrazenom na obr zku 6 v ktorom je stav Zima a program vykurovania je automatick Home zobrazuje nasleduj ce inform cie 1 De D tum Hodina s automatickou...

Page 8: ...PLOTA 6 Stav VYPNUT Dopyt IADNY Stav LETO Dopyt IADNY Stav LETO Dopyt TEPL VODA Stav ZIMA Dopyt IADNY Stav ZIMA Dopyt TEPL VODA Stav ZIMA Dopyt VYKUROVANIE 7 NASTAVEN TEPLOTA MIESTNOSTI NASTAVEN TEPLO...

Page 9: ...Room alebo Hot Water stla en m tla idla L je mo n vst pi do Menu Ot an m ovl da a sa zvisle pos vajte zoznamom polo iek a stla en m ovl da a vst pte do zvolenej podponuky Podmenu s r zne niektor zobra...

Page 10: ...10...

Page 11: ...j cu str nku ZRU TE vykonan akciu a vr te sa na predch dzaj cu str nku obr zok 7 Po zmene hodnoty v tomto pr pade jazyk language je mo n POTVR TE zmenu a vr te sa do av ho zoznamu Vr te sa SP na av zo...

Page 12: ...nej Program 3 Potvr te s Confirm Nov nastavenia sa ulo ia a m ete sa vr ti na dom cu obrazovku Ak NECHCETE ulo i zmeny stla te Cancel tla idlo bez potvrdenia 4 2 V ZNAM STAVU OFF predvolen V etky funk...

Page 13: ...z sobn ku zodpovedaj cej manu lnemu nastaveniu nastaven mu pou vate om cez okno Hot Water Set AUTOMATICK AUTOMATIC T denn asov rozvrh sa zhoduje s harmonogramom nastaven m pou vate om HOT WATER SETTI...

Page 14: ...o pravy nastavenia teploty To ist ako Room Set Temporary Manual a Party s vyl en Z dom cej obrazovky Room alebo Hot Water stla en m av ho tla idla je mo n vst pi do Menu pozri tie sekciu INTERFACE Roz...

Page 15: ...ernou jednotkou je kWe ekvivalent kW a vz ahuje sa na tandardn kotol potenci lne parametrizovan pomocou HEATING SETTINGS Menu v polo ke PARAM GRAPHICS POWER Pozn mka V padok nap jania 24 hod n ako aj...

Page 16: ...gomb ka sa men po iato n koncov hodnota intervalu pri om stl an m sa potvrdzuj daje prech dzaj ce do nasleduj cej premennej Po ukon en sa pravy ukon ia stla en m Confirm o bolo vykonan sa ulo stla en...

Page 17: ...rotiz mrazov funkcia Vstupom na str nku je mo n zapn vypn t to funkciu a nastavte pracovn teplotu Nastaven teplota nemrzn cej zmesi je teplota ktor zariadenie pou va na odoslanie po iadavky na ohrev n...

Page 18: ...noty ktor mi sa reguluje izbov teplota pri regul cii bez modul cie len pri hyster znej regul cii modul cii s vypnutou izbovou sondou ale so zapnut m pou it m izbovej sondy Pri nastavenej hodnote hyste...

Page 19: ...volen ako teplota dod vania Toto spodn obmedzenie ktor m e definova pou vate sa pou va oboje v modul cii a pevnom dod van a automaticky sa prisp sobuje pri prvom pripojen Z vis to od kotla a m rozsah...

Page 20: ...aje s visiace s t mto grafom bud definit vne zru en 6 4 GENERAL SETTINGS V EOBECN NASTAV Ponuka v eobecn ch nastaven pon ka mo nos zobrazenia a upravi nieko ko hlavn ch parametrov a opatren v eobecnej...

Page 21: ...st m fungova podobne ako stav Off Funkcie Hot Water ako aj vykurovanie miestnost bud zablokovan ak je aktivovan bude zaru en funkcia proti zamrznutiu Vstupom na str nku bude mo n upravi asov interval...

Page 22: ...tatn chyby odpor ame kontaktova servis 8 1 TECHNICK INFORM CIE Ve kos a hmotnos 128x99x36 mm kompatibiln s boxom 503 130 g Zdroj energie Bipol rny a nepolarizovan k bel V kon a spotreba Max 18V norm l...

Page 23: ...23 Pozn mky UC Riadiaca jednotka napr kotol GSM input GSM pripojenie OT Open Therm SX V avo DX Vpravo FW Firmv r OTC Kompenz cia vonkaj ej teploty OTC probe Extern sonda Slovn k pojmov...

Page 24: ...24...

Page 25: ...25 ATTACK OT80 TERMOSTAT MANUAL EN...

Page 26: ...UCTION 30 2 1 OVERVIEW 30 2 2 FIRST STARTING 30 3 INTERFACE 31 3 1 DISPLAY 31 3 2 ICONS 32 3 3 KNOB AND CONTEXTUAL BUTTONS 33 3 4 SURFING MENU 33 4 MODE STATUS AND PROGRAM 36 4 1 MODIF OF STATUS AND P...

Page 27: ...1 6 3 4 SET ECONOMY 41 6 3 5 TIME SCHEDULING 41 6 3 6 NO FROST FUNCTION 41 6 3 7 WATER FILLING 41 6 3 8 PARAM SETTINGS 41 6 3 9 PARAM POWER GRAPHS 43 6 4 GENERAL SETTINGS 44 6 4 1 LANGUAGE 44 6 4 2 DA...

Page 28: ...egitimate and even dangerous The constructor cannot be held responsible for damages to people animals or things if they are caused by faults in installation regulation and maintenance and by inappropr...

Page 29: ...most appropriate place for installation in order to guarantee the correct room temperature survey It is recommended to install the device at approx 150cm height from the floor away from doors windows...

Page 30: ...put picture 2 rotating encoder with push knob white and black display with backlight Right button Left button picture 3 2 2 FIRST STARTING Note RC21 communicates and is powered through the connection...

Page 31: ...nal probe is absent disabled Delivery See Menu HEATING SETTINGS section PARAM SETTINGS In the example shown on picture 6 in which the status is Winter and Heating program is automatic Home shows the f...

Page 32: ...Status SUMMER Demand NONE Status SUMMER Demand HOT WATER Status WINTER Demand NONE Status WINTER Demand HOT WATER Status WINTER Demand HEATING 7 ROOM SET TEMPERATURE SET TEMPERATURE 8 Progr STANDBY Pr...

Page 33: ...o enter to Menu Turn knob to scroll vertically the list of items and press knob to enter the selected submenu Submenus are different some of them show only information and others allow to change value...

Page 34: ...34...

Page 35: ...to previous page CANCEL what has been done and go back to previous page picture 7 After changing value in this case the language it is possible to CONFIRM the change and go back to left list Go BACK...

Page 36: ...firm and pass to the modification of following variable Program 3 With Confirm button the new settings are saved and you can go back to Home If you DO NOT want to save changes press Cancel button with...

Page 37: ...is enabled assuring a fixed out temperature or on tank corresponding to the manual set fixed by user through Hot Water Set window AUTOMATIC The weekly time schedule conforms to the one set by user HO...

Page 38: ...and Winter From Hot Water Home turn knob to enter the modification of Set temperature The same as Room Set Temporary Manual and Party functions excluded From Home whether Room or Hot Water pressing t...

Page 39: ...r tax purpose or for real power measuring The measure unit is kWe equivalent to kW and it is referred to a standard boiler potentially parameterized using HEATING SETTINGS Menu in the item PARAM GRAPH...

Page 40: ...ible to modify the time slots Turning the knob the start end interval value changes while pressing data are confirmed going to the following variable Once ended the modifications end by pressing Confi...

Page 41: ...the page it is possible to enable disable this function and set up the working temperature The antifreeze temperature set is the temperature used by the device to make a heating request to the minimum...

Page 42: ...ulation only during the hysteresis regulation modulation with disabled room probe but with room probe s use enabled At set value hysteresis the device switches off the request at set hysteresis it swi...

Page 43: ...e allowed as delivery temperature This lower limitation which can be defined by user is used both in modulation and fixed delivery and it is automatically adapted at the first link It depends on UC an...

Page 44: ...power saved in the graph 12 months notice all data related to this graph will be definitively cancelled 6 4 GENERAL SETTINGS The General Settings Menu offers the possibility to display and modify sev...

Page 45: ...be inhibited if enabled Antifreezing function will be guaranteed Entering the page it will be possible to modify the time interval for this function Rotating the knob it is possible to change the high...

Page 46: ...For all others we suggest to contact the assistance 8 1 TECHICAL INFORMATION Size and weight 128x99x36 mm compatible with box 503 130 g Power source Bipolar and not polarized cable Power and consumpti...

Page 47: ...47 Note UC Controlled Unit ex Boiler GSM input Telephone contact OT Open Therm SX Left DX Right FW Firmware OTC Outside Temperature Compensation OTC probe External probe Glossary...

Page 48: ...ke changes to specifications and content without prior notice Pictures and product specifications are only informative Price and offer changes are reserved V etky uveden inform cie s do asn podliehaj...