Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
225
Rev. 9 (12-2021)
Reference the Encoder Position
Complete this procedure to measure the physical distance between two encoders
on the straight section encoder assembly.
Redo this procedure if an encoder assembly is replaced on a straight section that
has a stationary mount installed.
1. Complete steps 1-4 of
Verify the Pallet Setup Stationary Mount Position
2. Click the
Reference Setup
tab.
3. Click the encoder that the stationary mount is aligned with.
4. Click
Capture Live Counts
.
The primary reference values display.
5. Click
Begin Sweep
.
6. Remove the pallet from the pallet setup removable locate:
a. Loosen the side thumb screw to release the pallet.
b. Raise the side thumb screw.
c. Slide the pallet to the right (~15 cm [~6 in.]).
TrakMaster calculates and displays the secondary reference values.
7. Click
Save Parameters
, located in the top right of the screen.
Encoder Configuration is selected by default on the Save Configuration dialog.
8. Click
OK
.
9. Note the following information for your records: your name, date, the pallet
number that was used for the procedure, and the removable locate number.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...