Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
223
Rev. 9 (12-2021)
Verify the Pallet Setup Stationary Mount Position
Complete this procedure to verify that the stationary mount is in the correct
position. A pallet with a correctly aligned encoder assembly (master or reference
pallet) is required for this procedure.
1. Install the pallet setup removable locate:
a. Align a removable locate with the
stationary mount.
b. Firmly hold the removable locate
back and to the left, and then
tighten the two (2) top thumb
screws.
2. Lock a pallet in position:
a. Lift the side thumb screw up.
b. Slowly position a pallet with a correctly adjusted encoder assembly
under the removable locate. This pallet is the master (reference) pallet.
Do not force the pallet against the datum of the removable locate
because this could shift the tooling out of position.
c. Lower the side thumb screw down.
d. Hold the pallet to the left, and
then lightly tighten the side thumb
screw to lock the pallet in position
against the datum.
Pallet setups can vary by ±5 microns
if inconsistent pressure is applied. Use
consistent pressure when locking a
pallet in position.
3. In the TrakMaster software, expand
Diagnostics
, and then click
Encoders
.
4. Click the
Encoder Strip Setup
tab.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...