Electronic Controls & Startup Procedures
remaining on the lamp life.
10. Dealer Information - This screen contains dealer con-
tact information. If you touch the right green arrow you
will see a scanable QR code which can be scanned with a
smart phone to obtain dealer information. (as shown in
Fig 5 & 5A)
11. Software Version - This screen displays the current
software version for the cercuit board. (as shown in Fig 6)
OPERATING INSTRUCTIONS
Your U.V. System is equipped with the ATS-287-2 U.V.
Lamp Detector and Timer circuit board which is designed
to provide a continuous monitoring system of the U.V.
lamp operational status. This is also equipped with an
internal and external fused surge protection system. This
solid state electronic circuit board provides the latest in
Touchscreen/U.V. lamp monitoring technology.
U.V. LAMP / CONTROL BOX START UP
PROCEDURE:
1. Make sure the U.V. lamp is inserted per instructions
into the quartz sleeve and U.V. chamber. Then plug
the U.V. lamp into the lamp connector.
2. Plug the electrical control box into a 120V wall plug
outlet.
3. Upon start up the U.V. lamp Detector and Timer
circuit board will perform a self diagnostic test. When
power is applied the circuit board will perform an
output check to see if lamp or probe is connected.
Once detected, the lamp will light and go into an
approximate 2 minute lamp optimization period. (as
shown in Fig 1 - 1D)
4. Quick Beep
5. The number 364 is displayed representing 364 days
remaining
6. Once warmed up, the logo and number of remaining
days is displayed.
7. Set the 1 Year Lamp Timer – WITH NEW U.V. LAMP\
Make sure the control box is plugged into the wall
outlet and the U.V. lamp is on. Touch the right green
arrow until “Reset lamp” is displayed. Touch the red
“reset” button and then touch the green check mark to
rest lamp for 1 year. (as shown in Fig 2 & 2A)
8. Snooze Alarms
• Touch to snooze alarm or touch the
button on display or control box.
9. Alarm screens
A. Lamp Out (as shown in Fig 3 & 3A)
• Circuit board has detected lamp out. Unplug
unit and check lamp connection, and plug the unit back
in.
B. Lamp Life Low (as shown in Fig 4)
• Circuit board has detected that there are 30 days
PFC © 2019 • www.aquat.com
Summary of Contents for Purificare PFC-12
Page 2: ...Purificare 2015 2 ...
Page 7: ...Purificare 2015 7 Installation Diagram PFC 2019 www aquat com ...
Page 9: ...Purificare 2015 9 Sample Screen Shots PFC 2019 www aquat com ...
Page 16: ...Purificare 2015 16 Circuit Board Layout PFC 2019 www aquat com ...
Page 21: ...Purificare 2015 21 Notes PFC 2019 www aquat com ...
Page 22: ...Purificare 2015 22 Notes PFC 2019 www aquat com ...
Page 23: ...Purificare 2015 23 Notes PFC 2019 www aquat com ...
Page 24: ...Purificare 2015 24 Warranty PFC 2019 www aquat com ...