Electronic Controls & Startup Procedures

remaining on the lamp life.
10. Dealer Information - This screen contains dealer con-

tact information. If you touch the right green arrow you 

will see a scanable QR code which can be scanned with a 

smart phone to obtain dealer information. (as shown in 

Fig 5 & 5A)

11. Software Version - This screen displays the current 

software version for the cercuit board. (as shown in Fig 6)

OPERATING INSTRUCTIONS
Your U.V. System is equipped with the ATS-287-2 U.V. 

Lamp Detector and Timer circuit board which is designed 

to provide a continuous monitoring system of the U.V. 

lamp operational status. This is also equipped with an 

internal and external fused surge protection system. This 

solid state electronic circuit board provides the latest in 

Touchscreen/U.V. lamp monitoring technology. 

U.V. LAMP / CONTROL BOX START UP 
PROCEDURE: 
1.  
Make sure the U.V. lamp is inserted per instructions 

into the quartz sleeve and  U.V. chamber. Then plug 

the U.V. lamp into the lamp connector. 

2.  Plug the electrical control box into a 120V wall plug 

outlet.

3.  Upon start up the U.V. lamp Detector and Timer 

circuit board will perform a self diagnostic test.  When 

power is applied the circuit board will perform an 

output check to see if lamp or probe is connected. 

Once detected, the lamp will light and go into an 

approximate 2 minute lamp  optimization period. (as 

shown in Fig 1 - 1D)

4.  Quick Beep
5.  The number 364 is displayed representing 364 days 

remaining

6.  Once warmed up, the logo and number of remaining 

days is displayed. 

7.  Set the 1 Year Lamp Timer – WITH NEW U.V. LAMP\ 

Make sure the control box is plugged into the wall 

outlet and the U.V. lamp is on. Touch the right green 

arrow until “Reset lamp” is displayed. Touch the red 

“reset” button and then touch the green check mark to 

rest lamp for 1 year. (as shown in Fig 2 & 2A)

8.  Snooze Alarms

 

• Touch      to snooze alarm or touch the  

button on display or control box. 

9.  Alarm screens

A. Lamp Out (as shown in Fig 3 & 3A)

 

• Circuit board has detected lamp out. Unplug 

unit and check lamp connection, and plug the unit back 

in.

B. Lamp Life Low (as shown in Fig 4)

 

• Circuit board has detected that there are 30 days 

PFC © 2019 • www.aquat.com        

Summary of Contents for Purificare PFC-12

Page 1: ... Info Installation Operation and Maintenance Manual CAUTION Read and Follow all safety rules and operating instructions before first use of product Ultraviolet Disinfection Systems MODELS PFC 8 PFC 12 PFC 20 ...

Page 2: ...Purificare 2015 2 ...

Page 3: ...on 6 Installation Diagram 7 Electronic Controls Startup Procedures 8 Sanitation Procedures 10 Maintenance 12 Unit Parts Breakdown 13 Circuit Board Layout 16 Wiring Diagram 17 Troubleshooting 18 Sterile Water Sample Precedures 19 Specifications 20 Notes 21 Warranty 23 Table of Contents PFC 2019 www aquat com ...

Page 4: ...ay cause an unsafe condition 7 Intended for indoor use Do not install this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperatures below freezing unless all the water has been drained from it and the water supply has been disconnected 8 Read and observe all the important notices and warnings on the water disinfectio...

Page 5: ...equipment may be required if these parameters cannot be maintained Flow rate must not exceed The PFC series has an unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber The chamber is fabricated out of 304 Stainless Steel These units come with an ultraviolet lamp designed with four pins at one end The quartz sleeve i...

Page 6: ...for proper wall support Use anchors with screws for sufficient support not included A lock nut secures the mounting bracket to the U V chamber If your piping system is subject to impulse pressure resulting in a water hammer condition a surge tank or other means must be provided to remove this condition otherwise this extreme shock pressure condition may rupture or fracture the quartz sleeve Make a...

Page 7: ...Purificare 2015 7 Installation Diagram PFC 2019 www aquat com ...

Page 8: ...to the lamp connector 2 Plug the electrical control box into a 120V wall plug outlet 3 Upon start up the U V lamp Detector and Timer circuit board will perform a self diagnostic test When power is applied the circuit board will perform an output check to see if lamp or probe is connected Once detected the lamp will light and go into an approximate 2 minute lamp optimization period as shown in Fig ...

Page 9: ...Purificare 2015 9 Sample Screen Shots PFC 2019 www aquat com ...

Page 10: ... Water in the well and storage tank should be treated with a strong chlorine solution to destroy disease organisms All pipelines and fixtures in the distribution system should be rinsed and flushed with chlorinated water Upon installation of a U V disinfection unit or yearly bulb replacement service disinfection with chlorine to initially flush the system is recommended to assure line sanitation p...

Page 11: ... and disinfect the water if necessary Plumbing Line Sanitation Only When installing an ultraviolet disinfection system a prefilter with sump may serve as a source to sanitize the water lines only For whole system disinfection follow procedure as outlined above Source The Pennsylvania State University College of Agriculture Cooperative Extension How to Sanitize a Water System Using Well Sanitizer P...

Page 12: ...trical connection Then remove brass end nut Install the quartz sleeve through the stainless steel threaded nipple until it is centered in the Quartz spring Use a small amount of plumber s grease and install the O ring around the quartz sleeve Avoid riding the O Ring on any threaded part of the nipple Hand tighten the brass end nut to form a compression seal around the quartz sleeve Avoid overtight...

Page 13: ...6 2 1 1 10 3 5 4 8 4 3 2 ITEM NO PART NUMBER DESCRIPTION QTY 1 ATS 476D Domed Quartz 1 2 ATS4 450 UV Lamp 1 3 ATS 268 Top Mounting Bracket 1 4 ATS 5172 Sightport Lens 1 5 ATS 5173 Orange 7 OD Viewport O Ring 1 6 ATS 5171 Sightport Nut 1 7 ATS5 409 Brass End Nut 1 8 ATS8 544 Quartz Sleeve Black 1 2 OD ORing 1 9 ATS5 410 Lock Nut 1 10 ATS8 546 Black 1 5 OD ORing 1 11 ATS 8GPM Flow Control 1 12 STS 8...

Page 14: ...NAL 25 TWO PLACE DECIMAL 010 THREE PLACE DECIMAL 002 UNLESS OTHERWISE SPECIFIED 10 31 16 B PFC 12 CUSTOMER BOM 6 8 1 3 5 2 10 7 9 4 11 14 12 13 ITEM NO PART NUMBER DESCRIPTION QTY 1 ATS1 759D Domed Quartz 1 2 ATS4 739 UV Lamp 1 3 ATS 5172 Sightport Lens 1 4 ATS 5173 Orange 7 OD Viewport O Ring 1 5 ATS 5171 Sightport Nut 1 6 ATS5 409 Brass End Nut 1 7 ATS8 544 Quartz Sleeve Black 1 2 OD ORing 1 8 A...

Page 15: ...ER 8 6 2 1 3 5 7 9 4 4 0 3 1 12 ITEM NO PART NUMBER DESCRIPTION QTY 1 ATS 832D Domed Quartz 1 2 ATS4 810 UV Lamp 1 3 ATS 5172 Sightport Lens 1 4 ATS 5173 Orange 7 OD Viewport O Ring 1 5 ATS 5171 Sightport Nut 1 6 ATS5 409 Brass End Nut 1 7 ATS8 544 Quartz Sleeve Black 1 2 OD ORing 1 8 ATS5 410 Lock Nut Lock Nut 1 9 ATS8 546 Black 1 5 OD ORing 1 10 ATS 20GPM Flow Control 1 11 ATS 271 Bottom Mountin...

Page 16: ...Purificare 2015 16 Circuit Board Layout PFC 2019 www aquat com ...

Page 17: ...st Power Display Backlight Touch Black White Green Red White Green White Blue Blue Yellow Yellow Red Red 2 1 2 1 J8 Ballast Status 2 1 Ballast Red Yellow 1 2 1 2 3 Blue Brown J6 Green Wire Crimp Green AC Power Cord UV Bulb Cable Panel Mounted Fuse Holder Wiring Diagram PFC 2019 www aquat com ...

Page 18: ...0V Electrical cord disconnected Check replace or outlet defective Defective U V lamp Replace Lamp Defective lamp ballast Check output voltage Replace ballast Loose open circuit wire Trace out and repair Leak at quartz nipple Defective or cracked O Ring Replace O Ring O Ring not seated properly Replace O Ring Cracked Quartz Sleeve Replace Quartz Sleeve PFC 2019 www aquat com ...

Page 19: ...n the sterile bottle or sterile container being used Holding the cap in a down position the operator should then hold his breath while taking the sample so as to avoid oral contamination of the sample The operator must not allow his finger to touch the inside of the cap or the neck of the bottle 4 After the sample has been taken the cap should immediately be tightly placed on the sample container ...

Page 20: ...oid acts as a fail safe shut off valve Providing extra protection for the system UV Probe UV dosage metering device This UV Probe reads only the 254 nm intensity output of the Ultraviolet Light within the UV treatment chamber Optional on PFC units only PFC 2019 www aquat com ...

Page 21: ...Purificare 2015 21 Notes PFC 2019 www aquat com ...

Page 22: ...Purificare 2015 22 Notes PFC 2019 www aquat com ...

Page 23: ...Purificare 2015 23 Notes PFC 2019 www aquat com ...

Page 24: ...Purificare 2015 24 Warranty PFC 2019 www aquat com ...

Reviews: