ATS CC186 User Manual Download Page 5

CC186 OR CC186/2 STAND-ALONE AND SYSTEM CLOCK                               

REV 05/16/01

APPLIED TECHNICAL SYSTEMS

PAGE 4

WWW.ATS-USA.COM

The first byte, byte 0, is the preamble.  It establishes communications with the CC186.  The
second byte, byte 1, is the address byte, address 0 or 15.  Byte 2 is the mode byte.  Up to
256 modes are possible providing complete control of all the 7 segment characters and
functions of the CC186.  Bytes 3 through 8 are associated with the six, 7-segment displays of
the CC186.  Byte 9 is the miscellaneous digit, which provides attributes such as colons, flash,
etc.

BYTE 0: 

START CHARACTER - An 11H is required to establish communications.

BYTE 1: 

ADDRESS BYTE - Address 0 or 15 is required to communicate to the
CC186.

BYTE 

2:

MODE 

BYTE 

Range is from 0 to 255.  This byte provides

complete control of all AE Series devices with the RS232 option
installed.  The modes are:

MODE O - ASCII character mode.  The AE device will display the AE
ASCII characters sent in bytes 3 through 8.  See the AE ASCII character
set at the back of this manual.

MODE 3 - 12 Hour Time/timer mode.  Bytes 3 through 8 are set as the
time, and time keeping begins.

MODE 4 - 24 Hour Time/timer mode.  Bytes 3 through 8 are set as the
time, and time keeping begins.

MODE 6 - Displays the software version installed in the AE device.

MODES 1 and 7 are reserved (AE Series Only)

MODES 8 - 255 are for future use.

BYTES 3 - 8: SIX CHARACTER BYTES - AE devices can have up to 6 digits.  The six

characters received are for displaying on these six digits.  These
characters will depend on the mode byte, byte 2, that precedes them.
They provide the words

for messages, the digits for setting time and

variable, and even 7-segment graphic characters.

BYTE 9:

MISCELLANEOUS DIGIT BYTE - This byte provides colons, AM/PM
indicators, and other attributes such as display flashing.

BIT 1 - Turns on the colons.  Colons are automatically turned on in the
time/timer mode, i.e. byte 2 = 3.

BIT 7 - Flash display.

Summary of Contents for CC186

Page 1: ...FN CC186M2 DOC CC186 AND CC186 2 STAND ALONE OR SYSTEM CLOCK ...

Page 2: ...re visible up to 50 feet away SPECIFICATIONS Operating voltage 12 VAC or 12 VDC 3 VA maximum A power jack is provided on the side panel for connecting power A 120 12 VAC power module P N 0900 7015 with mating connector is included Input Signal Receives a 10 byte message via a Two Wire RS232 signal from the host device A phone jack is provided on the side panel for connecting the incoming RS232 sig...

Page 3: ...ions remove the top screws one side at a time and add the optional angle brackets P N 1210 0102 to the top of the display as shown For optional side mount applications carefully remove the screws from the connector side and add the optional side mounting plate P N 1220 0303 2 to the side of the display as shown Do not remove the side panel A clearance hole will be required in the wall or mounting ...

Page 4: ...y power to the CC186 by plugging the power module into the 120 VAC power outlet The remote display will be blank The ON OFF button must then be pressed to turn on the display The digits will then show The display is now ready to receive RS232 data 10 byte message from the host device Stand Alone versions can be set manually to the correct time by the set switches located on the end panel The displ...

Page 5: ...e MODE O ASCII character mode The AE device will display the AE ASCII characters sent in bytes 3 through 8 See the AE ASCII character set at the back of this manual MODE 3 12 Hour Time timer mode Bytes 3 through 8 are set as the time and time keeping begins MODE 4 24 Hour Time timer mode Bytes 3 through 8 are set as the time and time keeping begins MODE 6 Displays the software version installed in...

Page 6: ... WWW ATS USA COM Using the AE21 Desktop Controller The AE21 Desktop Controller has built in routine for controlling AE CC Serial Displays Time of Day Elapsed Time and Data can be sent to the CC186 via the data cable provided with the AE21 Controller See the AE21 User s Manual for more details ...

Page 7: ...ATS warrants its products to be free of defects in material and workmanship for a period of 24 months from the date of purchase ATS will repair or replace any product returned to its authorized factory service center within the warranty period so long as there is no evidence that the product has been abused misused damaged by lightning overloads of any kind or water or altered in any way Products ...

Reviews: