background image

USER MANUAL 

PT-500 HI-ACCURACY THERMOMETER 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please read this user manual thoroughly before using 

this unit and keep it for your future reference. 

Summary of Contents for PT-500

Page 1: ...USER MANUAL PT 500 HI ACCURACY THERMOMETER Please read this user manual thoroughly before using this unit and keep it for your future reference ...

Page 2: ...CONTENTS 1 Safety Environmental Maintenance 1 2 Features 2 3 Specifications 3 4 Meter Description 4 5 LCD Display Description 5 6 Operating Instructions 6 7 Button Functions 7 8 Notes 8 9 Accessories 8 ...

Page 3: ......

Page 4: ...ed in this manual ENVIRONMENT CONDITIONS Altitude up to 2000 meters RH 90 Non Condensation Operating Temperature 20 C to 60 C MAINTENANCE Repairs or servicing not covered in this manual should only be performed by qualified personnel Wipe the unit with a dry soft cloth Do not use abrasives or solvents on this instrument Complies with EMC ...

Page 5: ...ntact thermometer with PT 100 input It is widely used for Hi Accuracy Applications Precise measurement PT 100 input Selectable 0 1 C or 0 01 C Resolution Large 34mm backlit LCD display DATA HOLD function C F selection Auto power off ...

Page 6: ...IFICATIONS Range 200 C to 400 C or 328 0 to 752 0 F Resolution Selectable 0 1 C or 0 01 C 0 01 C 80 to 200 C 0 1 C 200 C to 400 C Accuracy 0 05 C 80 C to 200 C 0 1 C Others Power 1 x 9V PP3 Battery Weight 292g ...

Page 7: ...4 4 METER DESCRIPTION PT 100 input connector LCD display C F selection button Resolution and measuring range selection button Hold button Backlight button Power ON OFF button Battery Compartment Cover ...

Page 8: ...5 5 LCD DISPLAY DESCRIPTION Sensor Type Low battery Indicator Temp units icon Reading Data Hold Icon Auto power off enabled Icon ...

Page 9: ... battery and close the battery compartment cover 2 Connect a PT 100 probe 3 Power on the meter to start measurement Note When the low battery icon appears replace the meter s battery During measuring the tip of the temperature sensor must be fully connected to the object to be measured ...

Page 10: ...f the backlight 3 Measurement Unit Button When powered on press the measurement unit button to toggle between C or F measurement unit 4 Level Button When powered on press the Level button to toggle the resolution to 0 01 C with a range of 80 C to 200 C or 0 1 C resolution with a range of 200 C to 400 C 5 Hold button When powered on press the hold button to freeze the reading on the display Press a...

Page 11: ...o not store or operate the meter in high temperature or humidity Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage 9 ACCESSORIES User manual 9V Battery Carry Case ...

Reviews: