- 24 -
same level with other series of the same stove; Please lift the equipment
rather than drag if you need to move it;
Please refer to P16“11. Schematic Diagram for Installation of Rear
Panel” for the installation methods of rear panel.
Supplied gas pressure regulator is factory set at 5”Natural Gas W.C,
and 10”L.P. Gas W.C;
The equipment can only be placed on the noncombustible
floor,and keep
a distance of at least 6 inches(152mm) to equipment’s both sides and back,
and keep a distance of at least 6 inches(152mm) to the bottom;
Do not put anything around the equipment, and on the counter top and bottom,
in order to avoid influencing combustion and air circulation;
Leave enough distance in front of the equipment to take apart the control
panel. All major parts, in addition to the burner remove from the front
intake-tube;
It may be necessary to adjust the balance of air input by authorized and
licensed technicians;
Thread glue must be resistant to the action of liquefied petroleum gases.
Warning! Use soap water or testing instrument to test whether piping
joint leaks or not before using, and forbid using an open flame to test!
After installing completely, you should check gas supply pressure. Use
a pressure gauge which is equipped with liquid (such as U-type pressure
gauge, the minimum value is 0.1mbar) or a digital pressure gauge to
test. Steps are as following:
●Remove top panel, and needle type pressure joint screw arbor (Fig.1),
then slip rubber tube of pressure gauge
over needle type pressure joint;
●Start the equipment in accordance with
the instructions, measuring gas supply
pressure (dynamic pressure) in the work
state;
●Access to the equipment if measured data
within the limits of Table 1, otherwise,
you will need to adjust gas pressure
regulating valve or contact gas supplier
to bargain; Figure 1
●Unplug pressure gauge after you accomplish pressure testing, then
install needle type pressure joint screw arbor. Important: must screw