Assembly position / location
Commissioning
Subplate surface finishing
Roughness index flatness ratio 0,01/100 (ISO 1101)
Ambient temperature
from -20°C to +70°C.
Fluid
Hydraulic oil as per DIN 51524 .... 535; for other fluids see section
Recommended viscosity
15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class
ISO 19/16, achieved with in line filters at 25
µ
m value to
β
25
≥
75 (recommended)
Fluid temperature
-20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction
As shown in the symbols of tables
and
Operating pressure
DKE
Ports P, A, B:
315 bar
For versions with proximity switches
Port T:
120 bar
for AC solenoids;
210 bar
for DC solenoids;
250 bar
for option /Y
(/FC, /FI and /FIE versions) port Y
DKER
Ports P,A,B:
315 bar
;
must be drained
Port T:
160 bar
for AC solenoid;
210 bar
for DC solenoids;
250 bar
for option /Y
Rated flow
See diagrams Q/
∆
p at section
Maximum flow
120 l/min
, see operating limits at section
For correct operation of AC version, the valve must be filled with hydraulic fluid, otherwise some vibra-
tions may occur. In this case fill the valve with oil by opening the screw
, see sketch at section
. A
check valve on T line aids to keep valve full.
12
4
MAIN CHARACTERISTICS OF DKE AND DKER DIRECTIONAL VALVES
5
NOTES
1
Options
A
= Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP
= prolonged manual override protected by rubber cap - see section
.
L, L1, L2, L3, LR
, see section
= device for switching time control (only for DC solenoids).
F *
= with proximity switch for monitoring spool position: see tab. E110.
Y
= external drain to be selected if the pressure at T port is higher than the max allowed limits (depending to the solenoid type) see “Operating limits” at
section
.
2
Type of electric connectors DIN 43650, to be ordered separately -
see section
.
SP-666
= standard connector IP-65 for direct connection to electric supply source.
SP-667
= as SP-666, but with built-in signal led.
SP-669
= with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
3 Spools
- spools
type
0/2, 1/2, 2/2
are only used for two position valves: single solenoid valves, type DKE*-163*/2; double solenoid valves type
DKE*-170*/2 and DKE*-175*/2.
- spools
type
0
and
3
are also available as
0/1
and
3/1
with restricted oil passages in central position, from user ports to tank.
-
spools type
1
is also available as
1/1
, properly shaped to reduce the water-hammer shocks during the switching.
-
other types of spools can be supplied on request.
14
11
13
Any position for all valves except for type - 170* (without springs) that must be installed with horizontal
axis if operated by impulses
(1) In case of 60 Hz voltage frequency the
performances are reduced by 10÷15% and
the power consumption is 80 VA for DKE and
90 VA for DKER.
(2) Average values based on tests performed at
nominal hydraulic condition and ambient/coil
temperature of 20°C.
(3) When solenoid is energized, the inrush cur-
rent is approx 3 times the holding current.
Inrush current values correspond to a power
consumption of about 280 VA for DKE and
320 VA for DKER.
12 DC
24 DC
110 DC
220 DC
110/50/60 AC
230/50/60 AC
110/50/60 AC
230/50/60 AC
SP-666
or
SP-667
SP-669
36 W (DKE)
39W (DKER)
95 VA (DKE)
105 VA (DKER)
(3)
36 W (DKE)
39 W (DKER)
SP-CAE-12DC
SP-CAE-24DC
SP-CAE-110DC
SP-CAE-220DC
SP-CAE-110/50/60AC (1)
SP-CAE-230/50/60AC (1)
SP-CAE-110DC
SP-CAE-220DC
SP-CAER-12DC
SP-CAER-24DC
SP-CAER-110DC
SP-CAER-220DC
SP-CAER-110/50/60AC (1)
SP-CAER-230/50/60AC (1)
SP-CAER-110DC
SP-CAER-220DC
6
ELECTRIC FEATURES
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Code of spare coil
DKE
DKER
4.1 Coils characteristics
Insulation class
H
(180°C) for DC coils
F
(155°C) for AC coils
Due to the occuring surface temperatures of the solenoid coils, the European standards EN563 and
EN982 must be taken into account
Connector protection degree
IP 65
Relative duty factor
100%
Supply voltage and frequency
See electric feature
Supply voltage tolerance
± 10%
Certification (only for DKER)
UL-CSA
certification - C UR US mark