4.3 Configuration set by hyper terminal console utility
1. Power off GW21W-MAXI.
2. Set the MODE switch SW1 to ‘OFF’ and SW2 to ‘ON’.
3. Use a PC to connect to GW21W-MAXI’s console with RS-232 cross over cable.
4. Power on GW21W-MAXI.
5. Open a hyper terminal program from your computer Start menu -> Programs -> Accessories ->
Communication -> hyper terminal, set COM1 parameters as follows.
-
Baud rate : 9600bps
-
Data bit: 8 bits
-
Parity: None
-
Stop bit: 1bit
-
Flow control: None
NOTE
:
At present time baud rate is fixed at
9600bps
for console port communication, RS-232C parameters
of your computer COM port and GW21W-MAXI must be the same.
6. Once hyper terminal is connected, type in username and password then the following hyper terminal
window appears.
7. The following configuration operations are totally the same as those configure by telnet.
8. After finishing console settings, power off GW21W-MAXI, put SW1 and SW2 back to the previous
setting.