Industrial Managed
Ethernet Switch
User Manual
錯誤
!
使用
[
常用
]
索
引標籤將
Heading
1,Product Manual
套用到您想要在此處
顯示的文字。
Page
62
of
191
categories of
PoE Alarm Event
listed here
:
PoE PD Power On
,
PoE PD Power Off
, and
Detect Total Power
. The
users also have choices for notification of the alarm(s) by Relay, Email, or Alarm LED. The user can check the
corresponding box for each type of notification. Please refer to Table 2.17 for the descriptions of PoE Alarm Setting.
Note that the alarm events can also be found in the Event Log (when
“Enabled” is checked” - see explanation in
Section 2.20.2
) or notified by Email (when “Email” is checked - see explanation in Section 2.20.3.3).
When “Relay”, “Alarm” and “Email” are checked, event log will show Warning/Alarm log.
Figure 2.67 PoE Alarm Setting
Table 2.17 Descriptions of PoE AlarmSetting
Label
Description
Factory Default
Detect Total Power Value
Set the total power value in Wattswhich will trigger
alarm event
.
Note that the value
‘0’
means that the
alarm event will not trigger
.
0
Enable
Check the box(s)
to enable alarm event
Unchecked
PoE
Alarm
Event
Select All
Check the box in front of this option to enable all
alarm events
-
PoE PD Power On
Check the box in front of this option to enable alarm
event when PoE PD is power on
.
-
PoE PD Power Off
Check the box in front of this option to enable alarm
event when PoE PD is power off
.
-
Detect Total
Power
Check the box in front of this option to enable alarm
event when managed switch can detect total power
exceeding the value set in the
Detect Total Power
Value
above
.
-
Relay
Check the box in this column so that alarm will turn
on an external relay circuit
.
Unchecked
Check the box in this column so that alarm will
send out an email notification
.
Unchecked
Alarm LED
Check the box in this column so that alarm will turn
on an external LED circuit
.
Unchecked