Table 2.63 Descriptions of Port State Event Warning Selection
Label
Description
Factory
Default
Port
Indicates eachport number
.
-
Port state
event
Disabled:
Disables alarm function, i
.
e
.
no alarm message will be sent.
Link Up:
Alarm message will be sent when this port/link is up and
connection begins.
Link Down:
Alarm message will be sent when this port/link is down and
disconnected
.
Link Up/Down
:
Alarm message will be sent whenever there
’s a
change, i.e. connection begins or connection disrupted
.
Disabled
In power status event warning, the users have two conditions to send notification (via
Relay
,
E
-
and
Alarm
LED
) which are
Power On
or
Power Off
.
Table 2.64 summarizes the Power Status event selection.
Table 2.64 Descriptions of Power Status Event Warning Selection
Label
Description
Factory
Default
Power
Indicate specific power supply
Disabled
Power status event
Disable: Disables alarm function
.
Power On: Sends an alarm when power is turned on
.
Power Off: Sends an alarm when power is turned off
.
Disabled
In System Log event warning, the user can only send notification via
E
-
. Table 2.65 describes the System
Log Level which can be selected for the System Log event notification.
Table 2.65 Descriptions of System Log Event Warning Selection
Label
Description
Factory Default
System log event
Disable: Disable power status detection.
0: (
LOG_EMERG
): Enable log level 0~7 detection.
1: (
LOG_ALERT
): Enable log level 1~7 detection.
2: (
LOG_CRIT
): Enable log level 2~7 detection.
3: (
LOG_ERR
): Enable log level 3~7 detection.
4: (
LOG_WARNING
): Enable log level 4~7 detection.
5: (
LOG_NOTICE
): Enable log level 5~7 detection
.
6: (
LOG_INFO
): Enable log level 6~7 detection
.
7: (
LOG_DEBUG
): Enable log level 7 detection
.
See note below for specific log level description
.
Disabled
*
NOTE:- Log levels
are inclusive
.
In other words, when log level is set to 0, an alarm is triggered whenever 0, 1,
2
…
6, and/or 7 happens
.
When log level is set to 5, an alarm is triggered whenever 5, 6, and
/
or 7 happens
.
0
:
Emergency
:
system is unstable
1
:
Alert
:
action must be taken immediately