117
Air conditioner service and maintenance
If air flow from the vents decreases, please check the refrigerates to see
whether it is enough in time, Methods for refilling the refrigerates
:
Step
□
1
Remove the front panel
,
watch the peep hole.
Step
□
2
If there are bubbles, this indicates that coolant is not enough, refill
the coolant (R134a) in time to let air conditioner work well.
Step
□
3
Refill the refrigerates.
Caution
■
Refill refrigerant in specified place to ensure safety.
。
■
Refrigerant fill capacity
450ml
.
■
Clean the surface dust off condenser periodically.
■
Clean air conditioner inlet filter periodically.
4-2.
Do-it-yourself Maintenance