background image

2

sPEcIfIcATIoNs

Generation ...................................................................................................... 2nd, 2nd+ 
Magnification................................................................................................... 2X (4X optional)
Objective:

Focal lenght................................................................................................... 50 mm

F  Number...................................................................................................  1.2

Focus...................................................................................................  Fixed

FOV ................................................................................................................. 20 deg. 
Reticle ............................................................................................................. Red On Green 
Windage & elevation adjustments ................................................................. 1/2MOA 
IR illuminator ................................................................................................... Super 450mw 
Battery life....................................................................................................... 30-50 hours 
Dimensions ........................................................................................ 250 x 95 x 85mm/10” x  3.6” x 3.2”  
Weight ............................................................................................................ 0.9kg/2 Lbs 
Diopter  adjustment  ........................................................................................  +/-5 
Operating temperature ........................................................................................ -40°C to +40°C

 

PREPARATIoN foR oPERATIoN  

Before getting started make sure to follow these 

steps:
• Install the battery into its housing with the polarity 

order shown on the main body of the unit.
• Switch on the scope with the protective lens cover 

still attached to the lens.
• Make sure that the green luminance of the light 

intensifier tube is present.
• Observe the scene, and adjust the diopter and/or 

lens for optimal image clarity.
• You may now enter a dark environment or simply 

shut the lights off in order to darken the room.
• Next, remove the lens cap/daylight filter.
• Finally, you may want to turn the infra red (IR) illuminator on. Notice the ability of the scope to 

see in total darkness with the aid of the IR illuminator.

oPERATINg

mouNTINg

1. Slightly loosen the  fixing screws on the 7/8” weaver mount built into the scope.
2. Place the scope on the weaver rail of the fire arm.
3. Tighten the  fixing screws.

NOTE:

 Fixing screws may need to be tightened after continuous shooting.

mouNTINg sysTEm

The ATN Night Vision Riflescopes Mounting System allows to change the position of the rif-

lescope flexibly on the weapon in relation to a shooter in combination with the fixed positions 

already available on the weaver rail. For this purpose in the base of the mounting bracket there 

is a rail with a fixing projection. There are two grooves in the mounting bracket for mounting 

this rail. Besides it is possible to change the position of the riflescope additionally by 1/3 of 

inch. For doing this one needs to about-face the rail.

Battery 

installation

Summary of Contents for Trident Pro2x-2

Page 1: ...ful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or in the United States for which a license or writ ten approval of the U S Government is required without first obtaining the required license or written approval from the Department of the U S Government having jurisdi...

Page 2: ...age 5 Diopter Battery housing Back up iron sights Mounting system IR brightness adjustment Digital Infra Red Illuminator Battery housing Fixation screw IR elevation IR windage IR focusing Afocal 2X magnifier optional Picatinny rails Lens cap LIGHT AND COMPACT DESIGN TOP NOTCH PERFORMANCE WITH PRO ORIENTED DESIGN 2X MAGNIFICATION WITH NEW F1 1 2 LENS 50MM OPTIONAL AFOCAL 2X MAGNIFIER ALL EXTERNAL S...

Page 3: ...order to darken the room Next remove the lens cap daylight filter Finally you may want to turn the infra red IR illuminator on Notice the ability of the scope to see in total darkness with the aid of the IR illuminator OPERATING MOUNTING 1 Slightly loosen the fixing screws on the 7 8 weaver mount built into the scope 2 Place the scope on the weaver rail of the fire arm 3 Tighten the fixing screws ...

Page 4: ...opter clock wise until it stops Then while looking through the diopter at a subject slowly turn the diopter back counter clockwise until the grain in the image is sharp NOTE We suggest that you focus the diopter during daylight with the cap on Operation Extendibility There are three detachable Picatinny rails on the body of the scope for additional lighting laser and other mission critical tools T...

Page 5: ... WINDAGE AND ELEVATION The vertical and horizontal adjustments for the ATN Trident Pro can be achieved by turning the elevation and windage adjust ment mechanisms remove dust caps first Each click equals 1 2 inch at 100 yards When reaching the maximum range of rotation do not use force CLEANING THE EYEPIECE You may need to clean the eyepiece of the riflescope from time to time in order to guarante...

Page 6: ... clicking occur while operating S If it occurs within the first five minutes of inserting new batteries it is normal and the device will resume normal operation soon thereafter If it occurs for more than 10 minutes contact your dealer or other authorized service representative for service instructions Q Dark spots on screen S This may be dust on the lens please clean according to instrutions They ...

Page 7: ... particular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed Limitation of liability ATN will not be liable for any claims actions suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole responsibility of the Customer ATN s sole undertaking is limited to providing ...

Page 8: ...nden Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2006 ATN Corporation ...

Reviews: