4-6
Table 4-1. Preventive Maintenance Checks and Services
SEQ.
NO.
ITEM TO
CHECK
CHECKING PROCEDURE
NOT FULLY MISSION
CAPABLE IF:
16
Remote
control
Take connector cap
off. Connect the
remote control to the
sight. Turn function
switch to STB position.
Press and hold the re-
mote control key. Look
for green glow in out-
put lens. Release the
key. Turn the switch to
OFF position.
Green glow absent.
17
Viewed
Image
Check for flickering,
flashing, bright spots,
edge glow, shading,
excessive fixed-
pattern noise (honey-
comb).
Excessive cosmet-
ic defects or fixed
pattern noise.
AFTER COMPLETING THE PMCS CHECkS LISTED
18
Replace protective
cap on output lens.
Disconnect remote
control and put remote
switch connector cap
on. Remove battery.
Place the sight and all
accessories to storage
case.