background image

4

OPERATION

• Take the monocular out of the case.
• Install the batteries into the housing with the polarity order as shown on the scope. Battery 

type: 3 Volt Lithium, #CR123A

• Press the button marked -/O to turn unit on with the protective lens cover still attached to the 

lens.

 Do not turn unit on in the daytime without the protective lens cap on.

 You should 

see a green glow in the eyepiece.

• Observe the scene and adjust the diopter for the optimal image clarity.
• You may now enter a dark environment or simply shut the lights off in order to darken the 

room.

• Next, remove the lens cap/daylight filter. Adjust the front lens for distance focus. You should 

not have to readjust the diopter.

• The unit will turn on and off automatically when you bring it to or take away from your eye. This is 

done by activating the proximity sensor. To activate the proximity sensor push the digital control 

marked “A”. You will notice the green LED change to red when the sensor is on.

• In order to assure the proper functioning of the proximity sensor, make sure that the protec-

tive glass surface of the sensor is always clean.

• To increase battery life the LED diodes will go off after 10 seconds.
• You will need to focus the objective lens for different distances.
• The handle on the MO-4 swivels easily from left to right allowing comfort of use for both right-

ies and lefties. To move the handle loosen the front lens and the eyepiece. The handle then 

will be adjustable for left- or right-hand use.

• Take your time learning about your “smart” scope. It will take practice to properly use the 

device. As you use this scope you will be able to improve your speed of focusing, as well as 

sharpness of image.

• Have fun and enjoy.

CLEANING THE EYEPIECE

You may need to clean the eyepiece of the MO-4 from time to time in order to guarantee top 

performance. When you receive your MO-4 you should check for dust on the eyepiece of the 

unit.
First  you  will  need  to  remove  the  eyepiece.  To  remove  the  eyepiece  you  will  need  to 

initially  loosen  2  set  screws  that  can  be  found  on  the  base.  Then  unscrew  the  eyepiece 

counter-clockwise to remove it.

NOTE: 

You do not have to remove the set screws completely, they are very small and easy to 

misplace.

CAUTION:

 Use only Photographic lens cleaning tissue on these surfaces. Be careful not to 

scratch, or smudge any of these surfaces. When using compressed air to blow dust away, make 

sure to avoid inverting the can while spraying. This may cause frozen propellent to exit the can, 

which can result in serious damage problems of the glass and phosphor screen.

STORAGE AND CARE

• If the device is not to be used for an extended period of time (more than 10 days) remove the 

battery.

• Avoid touching lenses. If Fingerprints or traces of dirt or dust appear clean surface with a 

Photographic lens cleaning tissue.

• Keep the lens cap/daylight filter on when not in use.
• The MO-4 is not harmful to the user or the environment.

Summary of Contents for Night vision Monocular MO-4

Page 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e MO 4...

Page 2: ...lity for any errors or inaccuracies that may appear in this book 2001 ATN Corp All right reserved Power button Digital control for IR Digital control for Proximity Sensor Objective lens protective cov...

Page 3: ...and enter their sleep mode All the controls and buttons are digital Even if your batteries are low don t worry the smart series will let you know Our MO 4 scope has a 3 button digital control panel t...

Page 4: ...he rubber eye cup from the MO 4 Screw the camera adapter onto the front of the lens on your Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the...

Page 5: ...ove the handle loosen the front lens and the eyepiece The handle then will be adjustable for left or right hand use Take your time learning about your smart scope It will take practice to properly use...

Page 6: ...icles can be cleaned following instructions in Cleaning Eyepiece section Q Screen becomes darker than in previous use S Replace batteries If the problem persists contact your dealer or other authorize...

Page 7: ...articular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings cos...

Page 8: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Reviews: