remember: If you twist and pull the Ir you will increase its distance of effectiveness while 

decreasing the angle and vice versa.

NOTE:

 The IR will automatically turn off when the unit’s main power is turned off.

low bATTery indicATor

The low battery indicator is another feature that is programmed into your “Smart” bioculars. If 

the batteries begin to lose its charge the Power leD starts to pulse indicating that you have to 

replace the batteries with new one.

Focusing 

NOTE:

 The Night Shadow inter-ocular distance could be adjusted manu-

ally.

to focus the night Shadow  you will need to adjust the diopter first. 

Simply turn the diopter clockwise until it stops. then, while looking to an 

object, slowly turn the diopter back counter-clockwise until the grain on 

the image becomes sharp.

NOTE: 

We suggest that you focus the diopter in daytime with the daylight 

filters on.

next, focus the front lens until the image and the grain are both sharp. 

when you are in low-light conditions and the daylight filter is off you may 

focus the front lens to obtain sharp image while the diopter should not be adjusted.

NOTE:

 The front lens should be readjusted as you view objects at different distances.

Power indicator

Summary of Contents for Night Shadow

Page 1: ...BIS Department of Commerce It is unlawful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign per...

Page 2: ...lergic reactions Cau t i o n Optional Accessories Power button Infra red illuminator ON OFF switch Proximity Sensor ON OFF switch Built in infrared IR illuminator Computerized proximity sensor Diopter...

Page 3: ...FICATIONS Magnification 3x 6x with Doubler 1st Gen 5x 10x with Doubler 2 CGT HPT WPT 3 3A 3P and G4 Intensifier Tube 1 2 CGT HPT WPT 3 3A 3P and G4 Lens System 6 elements F1 1 4 90 mm Field of View 14...

Page 4: ...rs When the oculars is brought to the user s eyes the bioculars will automatically turn on When removed from the eyes the device will turn off for this feature you have to engage the proximity sensor...

Page 5: ...cular distance could be adjusted manu ally To focus the Night Shadow you will need to adjust the diopter first Simply turn the diopter clockwise until it stops Then while looking to an object slowly t...

Page 6: ...s or your 35 mm camera lens Loosen the three set screws on the camera adapter Place the camera adapter over the Night Shadow eyepiece Tighten the three set screws to fit snugly to the Night Shadow eye...

Page 7: ...ght Shadow Screw the doubler onto the back of the lens Tighten the screw on the Doubler s side screw driver is provided Screw the lens with the Doubler back into the main body USING THE DOUBLER option...

Page 8: ...eadjust the front lens focusing for maximum clarity Remember the focus range of the bioculars is 20 to infinity The unit will turn on and off automatically when you bring it to or take away from your...

Page 9: ...he batteries Keep lens cap daylight filter on when not in use Avoid contact with dust steam and gas The Night Shadow is not harmful to the user or the environment Do not disassemble except to clean th...

Page 10: ...representative for service instructions Q Dark spots on screen S These are either cosmetic blemishes in the intensifier tube or dust particles The dust parti cles can be cleaned following instruction...

Page 11: ...oducts sold and services performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any t...

Page 12: ...fice 1341 San Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office The following countries can use our toll free number 00 800 9102 8620 Austria F...

Reviews: