background image

4

winDAge AnD eleVATion 

The vertical and horizontal adjustments for the Aries can be 

achieved by turning the elevation and windage adjustment 

mechanisms (remove dust caps first). Each click equals 1/2 

inch at 100 yards. When reaching the maximum range of 

rotation do not use force.

IR Brightness 

Adjustment

Battery 

Housing

Fixation 

Screw

IR Elevation

IR Windage

IR Focusing

You could change the IR control panel fitting your needs. The screw-tool included into the set 

should be used for weakening the fixing screw located on the IR. Rotate the IR placing at in 

the most convenient position. Tighten the screw with the screw-tool to fix the new position.

reTicle

Aries 350 Guardian reticle gives a clearly aiming point, 

even when hard-to-see game blends into the background. 

Thinner posts and crosshairs center section covers a 

minimum of the target and allow for less target coverage, 

making precision shots on small target easy.
Heavy posts stand out against cover and leads your eye 

directly to the center intersection, The result is fast precision 

aming.

The thin lines  

correspond to 

5 yards at 100 

yards distance

cleAning The eyepiece

You may need to clean the eyepiece of the riflescope from time to time in order to guarantee 

top performance. When you receive your riflescope you should check for dust on the 

eyepiece of the unit.
First you will need to remove the eyepiece. To do that you will need to initially loosen the 2 

set screws that can be found on the base. Then unscrew the eyepiece counter-clockwise to 

remove it.

NOTE:

 

You do not have to remove the set screws completely, they are very small and easy to misplace.

CAUTION:

 Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch 

or smudge any of these surfaces. When using compressed air to blow dust away, make sure to avoid 

inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause 

serious problems with the glass and phosphor screen

Elevation

Windage

Summary of Contents for Aries MK300

Page 1: ...he US Department of State or the US BIS Department of Commerce It is unlawful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or in the United States for which a license or written ap proval of the U S Government is required without first obtaining the required license or...

Page 2: ...ost compact 1st gen weapon sight on the market Measuring only 8 inches long and weighing less then 2 lbs the Guardian is one of the most rugged yet compact scopes made The accuracy on the MK300 is unparalleled thanks to our Red on Green reticle system Windage and elevation adjustments are as amazing 1 8 inch 100yards Combine this accuracy with other features such as a new super fast front lens sys...

Page 3: ...adjust the front lens for ideal focus Finally you may want to turn the infra red IR illuminator on Notice the ability of the Aries scope to see in total darkness with the aid of the IR illuminator OPERATING MOUNTING 1 Slightly loosen the fixing screws on the 7 8 weaver rail built into the scope 2 Place the scope on the dovetail mount of the fire arm making certain that the mount aligns with the re...

Page 4: ...should not be adjusted NOTE The front lens should be readjusted as you view objects at different distances IR Illumination Infra red IR Illuminators are common for night vision technology The IR light greatly enhances the performance of your scope while remaining almost totally invisible to the naked eye In dark environment power up the scope Now find a scene and examine it without the IR on then ...

Page 5: ...ecision shots on small target easy Heavy posts stand out against cover and leads your eye directly to the center intersection The result is fast precision aming The thin lines correspond to 5 yards at 100 yards distance CLEANING THE EYEPIECE You may need to clean the eyepiece of the riflescope from time to time in order to guarantee top performance When you receive your riflescope you should check...

Page 6: ...turn the unit off and wait 1 2 minutes before turning the unit back on Adverse atmospheric conditions such as fog smog or haze and a lack of ambient light moon or starlight may diminish the effective viewing distance All technical data for this unit was compiled in a controlled environment TROUBLEsHOOTING Q Flashes flickers or clicking occur while operating S If it occurs within the first five min...

Page 7: ...roducts sold and services performed by ATN to the Customer shall not be interpreted construed or regarded ei ther expressly or implied as being for the benefit of or creating any obligation toward any third party of legal entity outside ATN and the Customer ATN s obligations under this Agreement extend solely to the Customer ATN s liability hereunder for damages regardless of the form or action sh...

Page 8: ...an Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2009 ATN Corporation ...

Reviews: