CHAPTER 2. INSTALLATION
2.2. Mounting the assembly bracket
To mount the assembly bracket on a brick wall of sufficient
thickness, use the screw plugs that are supplied. When you
have determined the place of assembly, proceed as
follows:
1. Draw the position of the hole (1) in the strap of the
assembly bracket.
2. Use a masonry drill of 8 mm diameter to drill a hole with
a sufficient depth in the wall.
3. Keep the hole (1) in the assembly bracket in front of the
hole in the wall and fit one of the screws supplied
through the assembly bracket in the hole.
4. Align the assembly bracket with the aid of a spirit level.
5. Use a masonry drill of 8 mm diameter to drill holes with a
sufficient depth in the wall through the two bottom holes
(2) in the assembly bracket.
6. Fit two of the screws supplied in the bottom holes.
7. When using assembly brackets with ac lamping plate for
eccentric flue tube and air feed connection:
-
Use a masonry drill of 8 mm diameter to drill a hole
with a sufficient depth in the wall through the hole
in the clamping plate and fit a nail plug in this hole.
-
Fit the clamping plate at right angles.
8. Fix the assembly bracket firmly by tightening all screws.