4.3.10 CAN
The CAN controller provides all the features required to implement the serial communication protocol CAN defined by
Robert Bosch GmbH, the CAN specification as referred to by ISO/11898A (2.0 Part A and 2.0 Part B) for high speeds
and ISO/11519-2 for low speeds. The CAN Controller is able to handle all types of frames (Data, Remote, Error and
Overload) and achieves a bit rate of 1Mbit/sec.
The Atmel SAM4E has two CAN Controller with eight Mailboxes.
SAM4E-EK connects the CAN0 and CAN1 bus to the CAN transceiver SN65HVD234 (MN11 and MN12).
The extension connector (J13 and J14) type is RJ12 female socket.
Figure 4-9. CAN block.
R140
10K
(CANRX0)
R134
10K
C96
100nF
(CANTX0RS)
PE0
J13
CAN RJ12
1
1
2
2
3
3
4
4
5
5
6
6
+
C95
10uF
R135
0R
PE1
PB3
+3V3
R138
0R
(CANRX0EN)
R139
0R
+3V3
Rs
D
EN
R
CANH
CANL
VCC
GND
MN11
SN65HVD234
2
3
7
6
4
1
5
8
(CANTX0)
R137
120R
JP28
R151
10K
(CANRX1)
R141
10K
C99
100nF
(CANTX1RS)
PE2
PC15
J14
CAN RJ12
1
1
2
2
3
3
4
4
5
5
6
6
+
C98
10uF
R142
0R
PE3
PC12
R143
0R
R149
0R
+3V3
(CANRX1EN)
R150
0R
+3V3
Rs
D
EN
R
CANH
CANL
VCC
GND
MN12
SN65HVD234
2
3
7
6
4
1
5
8
(CANTX1)
CAN1
R148
120R
JP29
CAN0
PB2
J37-6
4.3.11 Display interface
The SAM4E-EK carries a TFT transmissive LCD module with touch panel, FTM280C34D. Its integrated driver IC is
ILI9325. The LCD display area is 2.8 inches diagonally measured, with a native resolution of 240 x 320 dots.
4.3.11.1
LCD module
The LCD module gets reset from the NRST signal. As explained, this NRST is shared with the JTAG port and the push-
button BP1. The LCD chip select signal is connected to NCS1; the jumper JP8 can disconnect it so that this PIO line is
available for other custom usage.
The SAM4E16 communicates with the LCD through PIOC where an 8-bit parallel “8080-like” protocol data bus has to
be implemented in software.