213
8331B–AVR–03/12
Atmel AVR XMEGA AU
• Bit 7:5 – Reserved
These bits are unused and reserved for future use. For compatibility with future devices, always
write these bits to zero when this register is written.
• Bit 4 – FDDBD: Fault Detection on Debug Break Detection
By default, when this bit is cleared and fault protection is enabled, and OCD break request is
treated as a fault. When this bit is set, an OCD break request will not trigger a fault condition.
• Bit 3 – Reserved
This bit is unused and reserved for future use. For compatibility with future devices, always write
this bit to zero when this register is written.
• Bit 2 – FDMODE: Fault Detection Restart Mode
This bit sets the fault protection restart mode. When this bit is cleared, latched mode is used,
and when it is set, cycle-by-cycle mode is used.
In latched mode, the waveform output will remain in the fault state until the fault condition is no
longer active and the FDF has been cleared by software. When both conditions are met, the
waveform output will return to normal operation at the next UPDATE condition.
In cycle-by-cycle mode, the waveform output will remain in the fault state until the fault condition
is no longer active. When this condition is met, the waveform output will return to normal opera-
tion at the next UPDATE condition
.
• Bit 1:0 – FDACT[1:0]: Fault Detection Action
These bits define the action performed, according to
, when a fault condition is
detected.
16.7.4
STATUS – Status register
• Bit 7:3 – Reserved
These bits are unused and reserved for future use. For compatibility with future devices, always
write these bits to zero when this register is written.
Table 16-1.
Fault actions
FDACT[1:0]
Group Configuration
Description
00
NONE
None (fault protection disabled)
01
Reserved
10
Reserved
11
CLEARDIR
Clear all direction (DIR) bits which correspond to the
enabled DTI channel(s); i.e., tri-state the outputs
Bit
7
6
5
4
3
2
1
0
–
–
–
–
–
FDF
DTHSBUFV
DTLSBUFV
STATUS
Read/Write
R
R
R
R
R
R/W
R/W
R/W
Initial Value
0
0
0
0
0
0
0
0