Captive Screw
Connecting
Captive screw connectors are an added feature on the UHD-H2H-44M matrix. The captive screw
connectors allow you to cut cables down to a suitable length, reducing cable clutter while providing
a more reliable connection.
The captive screw connectors have
a contact bar that is adjusted to
compress the wire against the
top contact plate. Use the screws
at the top of the connector to
compress the wire against the
contact plate.
When connecting the cables to the female captive screw connector it is important that the wires be
terminated correctly. The female captive screw connector has a contact plate at the top and must
have the wires touching it for signal to pass. When wired correctly
(see picture A)
the signal will pass,
incorrectly
(see picture B)
no signal will pass.
Clockwise
Counter
Clockwise
Turn the screws clockwise to
raise the contact bar to the
upper contact plate and hold
the wires in place.
Turn the screws counter
clockwise to lower the
contact bar to release the
wires.
A
B
One side of the optional IR cable is marked to differenciate pin outs.
There are two wires on the optional IR captive screw ready cable
(AT-LC-CS-IR-2M sold separately)
: signal
and ground. The signal wire is red and ground wire is black. The IR cable will plug into the IR IN
ports and connect to third party control systems.
Signal (S)
Ground (
)
S
IR IN
S
IR pin out will be
determined by the IR cable
and will connect as
(ground)
, and
S
(signal)