background image

AT-UHD-CAT-8

35

EDID lock

 

Click this toggle to switch the EDID lock mode.  When set to the 

LOCK

 position, the 

LOCK

 LED indicator on the front 

panel will glow solid blue.  Note that in this mode, all front-panel buttons are locked.

EDID mode

 

Click this drop-down list to select the desired EDID mode.

The Web GUI

EDID page

EDID

STD

ATL 1280x800 RGB 2CH

ATL 1080P 2CH

ATL 1366x768 RGB 2CH

ATL 1080P Multi CH

ATL 1080P DVI

ATL 1080P DD

ATL 1280x800 RGB DVI

ATL 1080P 3D 2CH

ATL 3840x2160@30 2CH

ATL 1080P 3D Multi CH

ATL 3840x2160@30 Multi CH

ATL 1080P 3D DD

ATL 3840x2160@60 2CH

ATL 720P 2CH

ATL 3840x2160@60 Multi CH

ATL 720P DD

EDID mode

Description

INT

Internal mode.  Uses the default internal EDID.

LEARN

Learn mode.  Reads the EDID of the sink device connected to the HDBaseT OUT 

1 port. Once the EDID is learned, it will be used by the connected source device to 

determine what video and audio formats can be sent to each sink device.  Refer to 

EDID Management (page 16)

 for more information.

INT EDID settings

 

Click this drop-down list to select the desired EDID.

EDID copy

 

Click this button to copy the selected EDID to the 

HDMI IN

 port.

Summary of Contents for AT-UHD-CAT-8

Page 1: ...AtlonaManuals DistributionAmplifiers AT UHD CAT 8 HDMI to HDBaseT Distribution Amplifier 4K UHD TM...

Page 2: ...AT UHD CAT 8 2 Version Release Date Notes 1 03 19 New format Version Information...

Page 3: ...oluntary and failure to register will not affect the product warranty To register your product go to http www atlona com registration Sales Marketing and Customer Support Welcome to Atlona Operating N...

Page 4: ...duct Warranty Terms New Products 10 years from proof of purchase date for hardware electronics products purchased on or after June 1 2013 3 years from proof of purchase date for hardware electronics p...

Page 5: ...s or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or excl...

Page 6: ...Do not use this product near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install or place this prod...

Page 7: ...the EDID 17 Selecting EDID Presets 18 Managing Users 19 Adding Users 19 Editing Deleting Users 20 Advanced Operation 21 RS 232 Control 21 Determining the Port Type 21 Cable Assembly 22 Pass through m...

Page 8: ...Ethernet PoE for HDBaseT receivers CEC display control Multi channel audio compliant EDID management Intuitive GUI based configuration using integrated web server TCP IP RS 232 and IR control Easy to...

Page 9: ...an HDMI cable from this port to a confidence monitor 13 RS 232 IR 1 8 Connect a control system or other DTE device to these ports for pass through zone control Each of these ports uses the associated...

Page 10: ...ports is associated to the respective HDBaseT OUT port This allows RS 232 pass through zone control of a display sink device that is connected to a PoE compatible receiver Control can be performed usi...

Page 11: ...v e n a d d i t i o n a l A T U H D E X 7 0 C T X d e v i c e s E t h e r n e t H D B a s e T LAN Display H D M I H D M I PO WER LIN K FW AT UHD EX 70 C RX AT UHD EX 70C RX Laptop AT UHD CAT 8 AT UHD...

Page 12: ...X LOCK LED indicator IMPORTANT If the AT UHD CAT 8 is receiving a DHCP IP address and the IP mode is changed to static then Telnet and web GUI communication will be lost 1 Make sure the AT UHD CAT 8 i...

Page 13: ...ddress by the DHCP server if present The System page page 37 in the web GUI allows the AT UHD CAT 8 to use either DHCP or static IP mode In order to access the web GUI the IP address of the AT UHD CAT...

Page 14: ...HDMI port on the AT UHD CAT 8 and the source display device Try a different HDMI cable HDBaseT 1 8 Blue Normal operation Signal integrity between the AT UHD CAT 8 and the connected receiver is good Of...

Page 15: ...ator will no longer be illuminated Using the Front Panel Using the web GUI 1 Login to the web GUI Refer to Introduction to the Web GUI page 31 for more information 2 Click System in the menu bar 3 Loc...

Page 16: ...powered Learning an EDID using the Front Panel HDBaseT OUT 1 HDMI Display AT UHD CAT 8 AT UHD EX 70C RX PO WE R LIN K FW AT UH D E X 7 0C RX AT UHD CA T 8 HDM I OUT IN HDB aseT 4 3 2 1 8 7 6 5 POW ER...

Page 17: ...between LOCK and UNLOCK states 4 Click the EDID mode drop down list and select LEARN 5 Click the COPY button to copy the downstream EDID to memory The AT UHD CAT 8 will now use the EDID of the downst...

Page 18: ...720P DD 1 Login to the web GUI Refer to Introduction to the Web GUI page 31 for more information 2 Click EDID in the menu bar 3 Make sure the EDID lock toggle switch is set to UNLOCK 4 Click the EDID...

Page 19: ...y default username and password for the admin user are listed below Username root Password Atlona 3 Click the Config tab 4 Click the Add button under the Edit column 5 Enter the desired username and p...

Page 20: ...Atlona a Click Config in the menu bar b Click the Edit button next to the user to be changed c Enter the new information for the user in the Username Password Edit dialog box d Click the Save Change b...

Page 21: ...owever this is not always the case If the port type is unknown then a multimeter can be used to determine whether the port is DTE or DCE Determining the Port Type DTE Pin Descriptions DCE Pin Descript...

Page 22: ...ove at least 3 16 5 mm of insulation from the TxD RxD and GND wires Cable Assembly When connecting a DTE device to a DCE device a straight through cable should be used A straight through cable is wire...

Page 23: ...he desired RS 232 IR port on the AT UHD CAT 8 Refer to Cable Assembly page 22 for instructions on preparing the cable 2 Connect an Ethernet cable from the desired HDBaseT OUT port to a receiver In thi...

Page 24: ...M NC NO 12V SIG GND 12V SIG GND 12V SIG GND 12V SIG GND 1 COM PONE NT HDM I 1 2 3 4 5 6 SERI AL 1 IR OUT SERI AL 2 L R DIGIT AL COAX OUT AUDI O OUT AUDI O IN ETHE RNET 2 3 4 VIDE O OUT 48V DC FACT ORY...

Page 25: ...Display Devices IR RS 232 IR 1 HDBaseT HDBaseT OUT 1 IR Emitter 2 COM NC NO COM NC NO COM NC NO COM NC NO 12V SIG GND 12V SIG GND 12V SIG GND 12V SIG GND 1 COMP ONEN T HDMI 1 2 3 4 5 6 SERIA L 1 IR OU...

Page 26: ...trolled 5 Place the IR emitter next to the source device R X G N D Controlling Source Devices IR Emitter RS 232 IR 1 HDBaseT HDBaseT OUT 1 IR Receiver Blu ray Player IR Remote Blu ray Player IR Signal...

Page 27: ...ER button will be blue Pressing the POWER button again will place the unit into standby mode and the POWER button will be red In standby mode no video signal will pass to the display sink device Howev...

Page 28: ...31 for more information The factory default username and password are listed below Username root Password Atlona 4 Click System in the menu bar 5 Click the Power button mode drop down list and select...

Page 29: ...CEC power on and power off commands by pressing the ON and OFF buttons near the bottom of the page 7 Press the POWER button on the front panel to power on or power off the display Note that the power...

Page 30: ...he POWER button on the front panel to power on or power off both the display and AT UHD CAT 8 Consumer Electronics Control CEC Atlona has confirmed proper CEC functionality with several current models...

Page 31: ...fer to IP Configuration page 12 The default static IP address of the AT UHD CAT 8 is 192 168 1 254 Introduction to the Web GUI 1 Launch a web browser 2 In the address bar type the IP address of the AT...

Page 32: ...lored bar near the top of the screen is the menu bar When the mouse is moved over each menu element it will be highlighted in light orange Once the desired menu element is highlighted click the left m...

Page 33: ...ion of firmware that the AT UHD CAT 8 is running Always make sure to check the AT UHD CAT 8 product page on the Atlona web site for the latest version of firmware Output 1 VALENS Version Output 8 VALE...

Page 34: ...38400 56000 57600 115200 Data bit Sets the number of data bits used to represent each character of data The following options are available 7 or 8 Parity Sets the parity bit which can be included wit...

Page 35: ...H ATL 3840x2160 30 2CH ATL 1080P 3D Multi CH ATL 3840x2160 30 Multi CH ATL 1080P 3D DD ATL 3840x2160 60 2CH ATL 720P 2CH ATL 3840x2160 60 Multi CH ATL 720P DD EDID mode Description INT Internal mode U...

Page 36: ...Password Enter the new password for the root username in this field Confirm New Password Verify the new password by retyping it in this field All User Login Settings Username Displays the username Pas...

Page 37: ...Click this toggle to set the login mode to either ON or OFF If this feature is set to ON then the AT UHD CAT 8 will prompt for both the username and password at the start of a Telnet session Use the...

Page 38: ...g the CEC protocol Power on and power off commands are sent over both the HDBaseT OUT and HDMI OUT ports Reset to Default Click the Factory Default button to set the AT UHD CAT 8 to factory default se...

Page 39: ...he computer containing the firmware to the same network where the AT UHD CAT 8 is connected 2 Go to the System page page 37 in the web GUI Choose File button Appendix 3 Click the Choose File button un...

Page 40: ...A to USB mini B cable between the PC and the firmware port on the AT UHD CAT 8 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDATE drive from...

Page 41: ...CAT6a CAT7 Solid Unshielded Twisted Pair UTP N A N A Shielded Twisted Pair STP Refer to the tables below for recommended cabling when using Altona products with HDBaseT The green bars indicate the sig...

Page 42: ...Parity Stop bit 115200 8 None 1 EDID EDID lock EDID mode INT EDID settings UNLOCK INT STD Config Username default Password default root Atlona System IP Mode Static IP Address default Netmask Gateway...

Page 43: ...olby TrueHD Dolby Atmos DTS DTS HD Master Audio DTS X Sample Rate 32 kHz 44 1 kHz 48 kHz 88 2 kHz 96 kHz 176 4 kHz 192 kHz Bit Depth Up to 24 bit Protocols Addressing DHCP static Management HTTP Telne...

Page 44: ...lution Distance 4K UHD Feet Meters 1080p Feet Meters HDMI IN OUT 15 5 30 10 CAT5e 115 35 200 60 CAT6 6a 7 130 40 230 70 Power Consumption 85 70 W Idle Consumption 18 40 W External Power Supply Input 1...

Page 45: ...I 39 using USB 40 I Installation 10 IP configuration 12 37 IR controlling displays 25 controlling sources 26 L LEARN button 16 LED indicators 14 Locking the EDID 17 the front panel 15 O Operating note...

Page 46: ...names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change without notice Actual products product images and o...

Reviews: