AT-HDVS-200-RX
31
RS-232 page
The Web GUI
RX RS232 1 / 2
The AT-HDVS-200-RX provides two RS-232 ports. Each port can be configured separately using the appropriate
drop-down list. The available values/settings for each drop-down list are the same for both ports. Click the
Save
button, next to each set of drop-down lists, to save the settings.
Zone
When the AT-HDVS-200-RX is connected to the AT-HDVS-200-TX, they are placed in “kit mode”. In this mode, these
drop-down list boxes will be disabled and the HDBaseT baud rate will be locked at 115200.
If the AT-HDVS-200-RX is connected to another HDBaseT device, such as the AT-UHD-CLSO-824, each of these
drop-down list boxes can be set to the baud rate of the HDBaseT port on the corresponding device.
The available settings for each drop-down list can be found in the table, above. Click the
Save
button, next to the
Zone
settings, to save the settings.
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 2400, 9600, 19200, 38400,
56000, 57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The following
options are available: 7 or 8.
Parity
Sets the parity bit, which can be included with each character to detect errors during
the transmission of data. The following options are available: None, Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing the client
to detect the end of a character stream. The following options are available: 1 or 2.