background image

www.atlona.com | toll free: 

1-877-536-3976

For International: 1-

408-962-0515

8

 SAFETY INFORMATION:

Safeguards

To reduce the risk of electric shock, do not

expose this product to rain or moisture.

power socket, hire an electrician to replace

your obsolete socket.

Do not modify the wall plug.

Doing so will void the warranty and safety

features.

This equipment should be installed near

the socket outlet and the device should

be easily accessible in case it requires

disconnection.

Precautions

FCC Regulations state that any

this equipment not expressly approved by

the manufacturer could void the

user’s authority to operate this

equipment.

Operate this product using only the

included external power supply. Use of

other power supplies could impair

performance, damage the product or cause

In the event of an electrostatic discharge,

this device may automatically turn off. If this

occurs, unplug the device, and plug it back

in.

Protect and route power cords so they will

not be stepped on or pinched by anything

placed on or against them. Be especially

careful of plug-ins, or cord exit points from

this product. 

Avoid excessive humidity, sudden

temperature changes or temperature

extremes.

Keep this product away from wet locations

such as bathtubs, sinks, laundries, wet

basements and swimming pools.

Use only accessories recommended by

hazards.

Unplug the product before cleaning. Use

a damp cloth for cleaning. Do not use

electrical shock. Some substances may

Never open or remove unit panels or make

any adjustments not described in this

manual. Attempting to do so could expose

you to dangerous electrical shock or other

hazards. It may also cause damage to your

AT-HD4-100SR. Opening the product will 

void the warranty.

Do not attempt to service the unit. Instead

disconnect it and contact your Authorized

ATLONA reseller or contact ATLONA

directly.

Summary of Contents for AT-HD4-100SR

Page 1: ...www atlona com toll free 1 877 536 3976 For International 1 408 962 0515 User Manual AtlonA HDMI 1 4 OVER SINGLE CAT5 6 7 EXTENDER WITH BI DIRECTIONAL IR and RS232 TRANSMITTER RECEIVER AT HD4 100SR ...

Page 2: ...e Contents 3 3 Features 3 4 5 Panel Descriptions 4 5 1 Transmitting Module 4 5 1 1 Front Panel 4 5 1 2 Rear Panel 5 5 2 Receiving Module 5 5 2 1 Front Panel 5 5 2 2 Rear Panel 4 6 Installation 6 7 Note 6 8 RS 232 Wiring Diagram 6 9 Troubleshooting 7 10 Atlona Product Registration 7 11 Safety Information 8 12 Warranty 9 ...

Page 3: ...ands can be sent from the remote location back to the main equipment center or the other way around Note The maximum usable distance depends on the quality and characteristics of the cables Higher resolutions and longer transmission distances require low skew cables 25ns 100m for the best performance Unshielded Cat6 7 with metal RJ 45 connectors and 568 B termination is recommended PACKAGE CONTENT...

Page 4: ...Input DDC signal 5 volts peak to peak Resolution 1080p 1920x1200 2k 2048x1080p and 4k 4096 3072 Deep Color 24 48 bits Video Bandwidth Up to 10 2GHz Vertical Frequency Range 50 60 Hz Audio Performance PCM 7 1ch Dolby Digital True HD DTS HD Master Audio Lip Sync Correction Yes 3D enabled Yes Power Consumption max 15 Watts Operation Temperature 0 C to 70 C Power Supply 5V 2A universal Housing Metal D...

Page 5: ... Panel 1 RS 232 Jack 5 HDMI Output 2 DC 5V Power Jack 6 IR Receiver 3 RJ45 Jack 7 IR Transmitter 4 HDMI Input local loop 1 IR Eye 2 HDCP Indicator 3 Activity Indicator 4 Power Indicator 5 2 2 Rear Panel 1 RS 232 Jack 2 DC 5V Power Jack 3 RJ45 Jack 4 HDMI Output 5 IR Transmitter 6 IR Receiver 1 2 3 4 5 6 7 1 2 3 4 1 2 3 4 5 6 ...

Page 6: ...ntrol or control system can be sent from the remote location back to the main equipment center or the other way around This is useful for ap plications where the user may still be using the factory remote controls for their products and those IR signals need to be routed to another room where the components are located This also allows for the use of 3rd party remote control systems where the IR i...

Page 7: ...N cable Wiring Shielding CAT5 CAT5e CAT6 Solid Unshielded UTP Shielded STP Stranded Unshielded UTP Shielded STP Termination Please use EIA TIA 568 B termination T568B at any time ATLONA PRODUCT REGISTRATION Thank you for purchasing this Atlona product we hope you ll enjoy it We also hope that you ll take a few moments to register your new purchase Registration creates an ownership updates At Atlon...

Page 8: ...discharge this device may automatically turn off If this occurs unplug the device and plug it back in Protect and route power cords so they will not be stepped on or pinched by anything placed on or against them Be especially careful of plug ins or cord exit points from this product Avoid excessive humidity sudden temperature changes or temperature extremes Keep this product away from wet location...

Page 9: ...or the remainder of the original warranty period or 3 year whichever is longer 3 NO OTHER WARRANTIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW ATLONA TECHNOLOGIES AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IM PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE PRODUCT AND ANY RELATED WRITTEN...