Atmosphere
User Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
– 52 –
General Settings Page for X-ANC
1. The General Settings page shows the connected accessory port.
2. Accessory Name – displays the editable name for this accessory.
3. Connected Port ID, and location of the accessory on the port wiring bus.
4. Import Settings – this allows a saved configuration file to be imported to duplicate an existing setup.
5. Export Settings – This saves the configuration file as a backup or to use for importing.
6. This “Locate” click on, click off button will toggle the LED on the accessory to locate where it is installed. Flashing will automatically
stop after 30 minutes.
7. The ANC processing data is shown in real time along with a button to unassign the sensor from the ANC and a jump button to the ANC settings
page. The ANC settings page also has a link on the sensor noise level meter “>” that returns you to this page.
Plug and Play Accessories Connection Rules
To guarantee good performance of all connected accessories, follow these rules:
1. Use CAT5e or CAT6 non-shielded cable (see cabling section) to connect accessories to the host processor bus-ports.
2. Up to 8 accessories can be daisy chained from a single port.
3. The “IN” port is connected to the upstream device (AZM or another accessory). (see image 3)
4. The maximum cable length from the AZM to the last accessory on the chain is 1000’(305m). (see image 4)
5. One audio wall plate (A-XLR, A-RCA, A-BT) can be used per bus-port. (see image 5)
6. Up to 16 accessories can be connected to a single AZM. (see image 6)
7. Up to 12 QR code virtual controllers can be used in addition to wired accessories.
Image 3