General Specifications

Rack Space  

 2RU (3.5") If ZCM-V2FP is Used.

Weight  

 ZCM-V2 Module – 5 lbs 
ZC1PRO System – 6 lbs 
ZC2PRO System – 11 lbs

Height 

 2.56" (65mm) - ZCM-V2 Module

Width 

 8" (203mm) - ZCM-V2 Module

Depth 

 10" (254mm) - ZCM-V2 Module

Mounting  

 2 Key Holes (7" Span) for Wall Mount  
Rack Plate (Included)

Amplifier / Control Specifications

Power Rating  

 9 Watts RMS into an 8

Ω

 Load with 12VDC Input

Inputs  

 RJ-45 Female on PCB  
(Accessible from Rack Ear Attachment Side)

Outputs  

  600

Ω

, 8

Ω

, 25V, and 70.7V

Power Source  

 IEEE 802.3af Compliant POE Network Switches / Local 12VDC – 18VDC PSU

Network Control  

 Multicast Enabled Networks

GPI Specifications

Relay Output  

 50V at 500mA Max

Input Minimum  

 1mA to Run on 50V Max

Microphone Specifications (Optional)

Sensitivity  

 -35 (±4dB) 
(0db = 1V/pa, 1kHz)

Impedance  

 Less than 2.2k

Directivity  

 Omnidirectional

Frequency  

 20Hz – 20kHz

Max. Operation Voltage  

 10V

Standard Operation Voltage  

 2V

Current Consumption Max.  

 0.5 mA

Sensitivity Reduction Within 

 -3dB @ 1.5V

S/N Ratio  

 More than 62dB

Summary of Contents for Zone Controller Pro ZCM-V2

Page 1: ... server on the network Next the unit will listen for an SLP broadcast from InformaCast ControlKom software telling the unit where the service is running on the network Once the ZCM V2 identifies the software s location it will request the InformaCastSpeaker cfg file and register The MAC address of the ZCM V2 will then show in the Unidentified Speakers page in the software Please refer to the insta...

Page 2: ...the GPI Out closure when audio is playing use a tag like this GPIO while_audio_output 1x The first digit controls GPI Out 1 the second controls GPI Out 2 1 means to close it when audio is playing open it otherwise 0 means to open it when audio is playing close it otherwise x means the that GPI Out is not affected by audio playing Example InformaCastSpeakerConfiguration Servers registration interva...

Page 3: ...ntil a broadcast is active Mounting One or Two Zone Controller Pro units can be rack mounted side by side via a 2RU face plate This 2RU face plate is included with the ZC1PRO and the ZC2PRO systems The faceplat may be purchased separately using part number ZCM V2FP Or wall mount via the 2 keyholes Use Only if 802 3 af Compliant POE Switch Not Available Input Output 1601 Jack McKay Blvd Ennis TX 75...

Page 4: ...m ZCM V2 Module Mounting 2 Key Holes 7 Span for Wall Mount Rack Plate Included Amplifier Control Specifications Power Rating 9 Watts RMS into an 8Ω Load with 12VDC Input Inputs RJ 45 Female on PCB Accessible from Rack Ear Attachment Side Outputs 600Ω 8Ω 25V and 70 7V Power Source IEEE 802 3af Compliant POE Network Switches Local 12VDC 18VDC PSU Network Control Multicast Enabled Networks GPI Specif...

Reviews: