background image

 AtlasSound.com 

– 8 – 

Specifications are subject to change without notice.

Owner’s Manual

AP-S15RTHR

AC Power Conditioner & Distribution Unit

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

Rear Panel Features Description

1. AC Mains Input

  

Connect the IEC 14 Gauge 12' (4m) power cord to a 15A 120VAC outlet to provide power to the AP-S15RTHR.

2. AC Mains Input IEC Power Cord Retainer

The AP-S15RTHR incorporates an IEC Power Cord retainer bracket to prevent the cord from coming loose. See IEC power cord retainer 
bracket installation. 

3. AC Power Outlets

 

The AP-S15RTHR features six NEMA 5-15P AC outlets. There is one Unswitched outlet on the front and one on the rear of the unit. 
There are four Switched AC outlets on the rear of the unit for a total of six AC outlets. These four Switched AC outlets are “Live” when 
the front panel power switch is in the On position and the Remote Turn On terminals are shorted. The two Unswitched outlets are 
always live if the power cord is connected to 120VAC.

4. Remote Activation

 

There are two methods to remotely activate the AP-S15RTHR: 
 

A. External Switch

 - The Ext SW terminals are connected to a latching type dry contact closure to activate the AP-S15RTHR.  

  

Note:

 This feature can be used for Emergency Power Down (EPD), when tied into a normally closed latching contact closure  

 

  (e.g. Fire Panel).

 

B.  DC Voltage

 - When you apply 5V - 24VDC to the Return terminal the unit will activate. See “Remote Activation Drawings” for  

 

  details. It may be required to connect a Ground Pin from the AP-S15RTHR to the DC sending unit.

5. DC Voltage Output 24V 2000mA

 

The AP-S15RTHR features a 24VDC 2000mA output to power external devices. This 24VDC output provides enough current to power 
several of the Time Saving Device (TSD) preamps, mixers or amplifiers reducing or eliminating the need for external DC power supplies. 
The DC output works in conjunction with the Switched AC outlets. There two sets of DC - & + connections in parallel for convenience.

Installation

Before installing, read the entire manual to ensure proper understanding of operation and that all features are being utilized. The  
AP-S15RTHR can be placed on a shelf or rack mounted in a half width rack or a 19" width rack. When rack mounted, placement within 
the rack is flexible however the AP-S15RTHR should be within 6' of a dedicated 15A AC outlet. When rack mounting, use rack rail type 
screws of 

10

32

" x 1". Always make sure the 15A outlet is properly inspected by a certified electrician prior to connecting the AP-S15RTHR. 

Make sure to inspect the equipment that will be connected to the AP-S15RTHR to ensure it does not exceed 15A total amperage draw. 

1

2

3

5

4

Summary of Contents for Atlas Power AP-S15RTHR

Page 1: ...e subject to change without notice Owner s Manual AP S15RTHR AC Power Conditioner Distribution Unit 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AP S15RTHR AC P...

Page 2: ...01 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Table of Contents Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Descript...

Page 3: ...he cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over 13 Unp...

Page 4: ...er cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Replace the protective cover over th...

Page 5: ...RTHR can be remotely activated by using dry contact closure or via a 5V 24VDC voltage Either method can be triggered by using one of the optional Atlas WPD wall plate switches that feature a custom la...

Page 6: ...or EPD Emergency Power Down to Integrate with Fire Control Panels Remote Status LED Power Terminals RFI Noise Filtering to Reduce Radio Frequency Interference EMI Filtering to Reduce Electromagnetic I...

Page 7: ...On position and AC voltage is present the power switch will illuminate Note This does not mean the switched AC outlets are active For the switched AC outlets to be active the remote turn on terminals...

Page 8: ...is feature can be used for Emergency Power Down EPD when tied into a normally closed latching contact closure e g Fire Panel B DC Voltage When you apply 5V 24VDC to the Return terminal the unit will a...

Page 9: ...provide power to the AP S15RTHR by aligning the pins of the cord to the pins on the chassis and inserting the cord Press firmly to assure a good connection Remove the two screws from the chassis of t...

Page 10: ...enix Type Connection 24VDC 2000mA Output 4 Position 3 5mm Phoenix Type Connection AC Mains IEC Power Socket 15A 1800W Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC...

Page 11: ...d com Specifications are subject to change without notice Owner s Manual AP S15RTHR AC Power Conditioner Distribution Unit 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 7...

Page 12: ...e of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement u...

Reviews: