background image

 AtlasSound.com 

– 4 – 

Specifications are subject to change without notice.

Owner’s Manual

AP-S15 Power Conditioner & 

Distribution Unit

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

CAUTION –  When Installing the Product

• 

 

 

Plugging in or unplugging the power cord with wet hands may result in electric shock.

 

 

Never move the unit with the power cord plugged into the wall, as damage to the power cord may result. 

 

 

When unplugging the cord from the wall, grasp the plug, NOT the cord.

 

 

Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or 
steam are present. Fire and electric shock may result.

 

 

Keep all sides of the unit at least 3

1

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

WARNING – When the Device is in Use

 

 

 

To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to Atlas 
Sound.

 

 

Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from 
the AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the product as this may cause fire or electric 
shock:

 

 

 

Smoke or strange smell coming from the unit.

 

 

 

If the product falls or the case is damaged.

 

 

 

If water or any metallic objects falls into the product.

 

• 

 

 

If the power supply cord is damaged in any way.

 

 

 

If the unit is malfunctioning.

 

 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in 
electric shock or fire.

 

 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric 
shock may result.

 

 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

 

 

Never exceed the wattage on the product when connecting equipment. Fire and/or property damage may result.

 

 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.

 

 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy 
objects on the power cord, including the product itself, doing so may result in fire or electrical shock.

 

 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic 
disaster may result.

 

 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.

 

CAUTION – When the Device is in Use

 

•   Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In 

addition, the product itself may fall and cause injury and property damage.

•   Contact Atlas Sound for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in 

heat buildup and fire.

•   Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or 

inside the wall outlet.

•  When cleaning the unit or the unit is not to be operated for an extended time period, unplug the power cord from the wall.

Summary of Contents for AP-S15

Page 1: ...tions are subject to change without notice Owner s Manual AP S15 Power Conditioner Distribution Unit 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AP S15 Power Conditioner Distribution Unit ...

Page 2: ...Power Conditioner Distribution Unit 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Table of Contents Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Features 6 Rear Panel Features 6 Installation 6 Specifications 7 Warranty 8 ...

Page 3: ...moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the appar...

Page 4: ...ntilation holes of the product s cover as this may result in electric shock or fire Do not place any containers with liquid or metallic objects on the top of the product If any liquid spills into the unit fire or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when conne...

Page 5: ... amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time The AP S15 s circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds thus ensuring virtually trouble free protection The AP S15 offers power management control noise filtering and spike surge protection making it the...

Page 6: ...P S15L on or off press the switch to the ON or OFF position The power switch will illuminate when in the On position Rear Panel Features 1 AC Mains Input Connect the 9 3m power cord to a 15A 120VAC outlet to provide power to the AP S15 2 AC Switched Power Outlets These six outlets are Live when the front panel power switch is activated 3 AC Unswitched Power Outlets These two outlets are always Liv...

Page 7: ...lets total 6 Switched 2 Unswitched AC Mains Power Cord 9 3m 14 gauge Technical Data Current Rating 15 amps Operating Voltage 102VAC 132VAC Min Spike Clamping Voltage 460VRMS 3 000A Max Spike Clamping Voltage 6000V Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20µs Maximum Surge Current 6 500A Energy Rating 2ms 200 Joules Noise Attenuation EMI RFI 10dB 10kHz 40dB ...

Page 8: ... original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned products a written...