Atlas AA30PHD Owner'S Manual Download Page 8

 AtlasSound.com 

– 8 – 

Owner’s Manual

AA30PHD

30W Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

Rear Panel 

7. VOX Mute Sensitivity Control  

Input 1 signal can be used to trigger or activate a mute command. When an input is set to Mute Receive via the corresponding DIP 
switch, the input associated to the switch will be muted when a signal is applied to Input 1. The VOX Mute Sensitivity Control adjusts 
how sensitive the mute circuitry from Input 1 reacts. Setting the control fully counter-clockwise will lower the sensitivity, where a 
higher amplitude signal will be required at Input 1 to trigger the mute send circuits. Fully clockwise will raise the sensitivity of the mute 
circuits, where a lower amplitude signal will trigger a mute send. Calibration of this control in conjunction with the microphone to be 
used is very important to assure the proper amount of signal from the mic is enough to trigger the mute circuits. If it is not calibrated 
properly, the mute may not be triggered when a weak voice vs a strong voice uses the mic.

8. Zone 2 Output Port

This terminal provides a 600

Ω

 unbalanced output that is typically connected to a PBX music on hold port, also known as MOH. Inputs 

are assigned to the Zone 2 bus via switch associated with the input. 

Note:

 10k

Ω

 output impedance is available via the internal shunt 

selection.

9. Zone 2 Output Level Control

This control will vary the level at the Zone 2 output terminals. Fully counter-clockwise (0) is Off, fully clockwise (10) is the maximum 
output level. The Zone 2 level control is PRE Inputs 1, 2, 3 and 4 volume controls.

10. Multi Function DIP switch

Understanding the functionality of the DIP switches is key to maximizing the versatility of the AAPHD Series. When a switch is in the 
up position, the function is “OFF or assigned to the feature stated”; when a switch is in the down position, the function is “ON or 
assigned to the feature stated “.

 • 

DP SW #1 - Zone 2 Assign Input 3

 - When “ON”, Input 3 signal will be routed to the Zone 2 Output terminals. The signal    

 

 

routed is PRE the front panel level control. 

 • 

DP SW #2 - Zone 2 Assign Input 2 

- When “ON”, Input 2 signal will be routed to the Zone 2 Output terminals. The signal    

 

 

routed is POST the front panel level control.

 • 

DP SW #3 - Mute Receive Input 3 

- When “ON”, Input 3 signals will be muted if a signal is present on Input 1 or if the  

 

 

 

Remote Mute Terminals are shorted together.

 • 

DP SW #4 - Mute Receive Input 2

 - When “ON”, Input 2 signals will be muted if a signal is present on Input 1 or if the  

 

 

 

Remote Mute Terminals are shorted together.

 • 

DP SW #5 - Input 1 Phantom Power 

- 24VDC is active when Input 1 is set to Mic mode and the switch is in the ON position.  

  

Note:

 Only use this feature if you are using condenser microphones, otherwise leave in the “OFF” position.

 • 

DP SW #6 - 

When in the “MIC” position, Input 1 will accept microphone level signals; when in the “Line” position, Input 1 will  

 

 

accept line level or telephone signals.

11. Amplifier Outputs

For loudspeaker connections, connect as follows or proceed to the setup section for typical wiring schemes.
 • 

COM

 - Speaker common or negative connection

 • 

4

Ω

 - Connect to direct coupled loudspeakers

 • 

25V

 - Connect to transformer coupled loudspeakers

 • 

70V

 - Connect to transformer coupled loudspeakers

12. Power Cord

Connect this grounded power cord to 120VAC circuits only. Serious damage may result otherwise.

13.  Ground Terminal

Connect this terminal to electrical ground as required by local codes.

Signal

Peak

Limit

Power

PHD

3

5

6

4

3

2

1

9

0

10

8

7

2

5

6

4

3

2

1

9

0

10

8

7

1

5

6

4

3

2

1

9

0

10

8

7

AA30PHD

Professional Mixer Amplifier

Power

120V AC 60Hz 90W

Treble

Bass

1

Input 3

Off
On

2

Input 2

Off
On

3

Input 3

Off
On

Zone 2 Assign

Mute RCV

Input 1

4

Input 2

Off
On

5

Phantom

Off
On

6

Line/Tel

Mic

Chan 2

Chan 3

Sum In

Sum In

G –

RMT

Mute

+

+

VOX

Sens

Channel 1 - Input

Level

+

Zone 2 - Output

– +

600

Ω

CLASS 2 WIRING

COM 4

Ω

25V 70V

Amplifier Output

PA Amplifier

Model AA30PHD

Output Rated 30W

Designed and Engineered

by Atlas Sound

Made in China

Summary of Contents for AA30PHD

Page 1: ...com Specifications are subject to change without notice Owner s Manual AA30PHD 30W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA30PHD 30W Mix...

Page 2: ...rtant Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 9 Common Amplifier Failure Conditions 9 Trouble S...

Page 3: ...plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the r...

Page 4: ...wer cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the safety ground termi...

Page 5: ...ered for reliability the Atlas Sound AA30PHD will provide years of service and flexibility in background music and paging applications Key Features 30W Into 25V 70 7V and 4 Loads Automated Diagnostic...

Page 6: ...tem using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD Load Impedance Testing System Note...

Page 7: ...nals To select between Mic or Line input levels refer to the DIP switch chart on the rear of the amplifier for feature assignment If connecting an unbalanced line level input tie short the G and termi...

Page 8: ...function is ON or assigned to the feature stated DP SW 1 Zone 2 Assign Input 3 When ON Input 3 signal will be routed to the Zone 2 Output terminals The signal routed is PRE the front panel level cont...

Page 9: ...stem after everything is installed A Measure the speaker system using a true audio frequency impedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B...

Page 10: ...t set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visually looking at each speaker is to have...

Page 11: ...f the diagnostic test the Limit indicator may flash Yellow for a few seconds until an accurate diagnostic reading has been completed continue to hold the PHD switch in for 5 seconds to assure the test...

Page 12: ...Replace the knobs with security covers Atlas Sound part number AAVCC 5 available in quantities of 5 Front Panel Knob Security Cover or Signal Peak Limit Power PHD 3 5 6 4 3 2 1 9 0 10 8 7 2 5 6 4 3 2...

Page 13: ...lasSound com Specifications are subject to change without notice Owner s Manual AA30PHD 30W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block D...

Page 14: ...r 70V Distributed Systems Level Controls Inputs 1 3 Rear Panel Inputs Mic Line Balanced Qty 1 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Tone Controls Bass 6dB 100Hz Treble 6dB 10k...

Page 15: ...nput Sensitivity Impedance Input 1 Mic Mode 5mv No Trim 1200 Input 1 Line Mode 316mV 10dBV 1200 Input 2 3 316mV 10dBV 10k Signal To Noise Ratio Mic 55dB Line 55dB Telephone 55dB Input 2 3 75dB Phantom...

Page 16: ...eturns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing cost...

Reviews: