Atlas AA200PHD Owner'S Manual Download Page 20

 AtlasSound.com 

– 20 – 

Specifications are subject to change without notice.

Owner’s Manual

AA200PHD-CE

200W Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

AA200PHD-CE Specifications

Outputs

Main 

Transformer Coupled, Balanced, 4

Ω

, 50V, and 100V. Class 2 Rated, Removable 4 Position PHX  

 

5.08mm Pitch, Accepts up to 12 Gauge Wire, 12A Rating

Zone 2 

Unbalanced 600

Ω

 / 10k

Ω

, Max 1.0V Out, Removable 2 Position PHX 3.50mm Pitch, Accepts Up  

 

to 18 Gauge Wire, 8A Rating

Pre Out 

RCA, Unbalanced 150

Ω

 

 

Technical Data

Inputs  

Total Qty 6

Frequency Response 

50Hz-15kHz +/- 3dB

Thd+N 

0.5% Or Less, At 1kHz, Rated Output

Input Sensitivity / Impedance 

Input 1, 2, 3, 4  

Mic Mode 5mv, No Trim, 1200

Ω

 

Input 1, 2, 3, 4  

Line Mode 316mV (-10dBV) 1200

Ω

 

Input 4  

 

3.5mm Summed, 316mV (-10dBV) 10k

Ω

 

Input 5, 6   

RCA Unbalanced Summed 316mV (-10dBV) 10k

Ω

Signal To Noise Ratio 

Mic 

 

>55dB

 

Line   >55dB

 

Telephone  

>55dB

 

Input 5, 6   

>75dB

Phantom Power 

24VDC

 

Power Requirements

AC Mains 

220V 50Hz

AC Cord 

2M, 16 gauge, NEMA 5-20P

Idle Power 

0.18A, 21W, 73 BTU

Average Power 

1

/

3

 Rated Output 

2.9A, 348W, 1187 BTU

Max Power (20mS Burst) 

4.5A, 540W, 1842 BTI

 

Mechanical

Chassis 

 Steel 

Finish 

Black Paint on Front and Top

Dimensions  

16.54" x 3.66" x 14.6" (420mm x 93mm x 422mm)

Weight  

26 lbs (11.6kg)

Summary of Contents for AA200PHD

Page 1: ...Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA200PHD CE 200...

Page 2: ...tant Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel Description 6 Rear Panel Description 7 PHD Diagnostic System Test 12 Common Amplifier Failure Conditions 12 Trouble...

Page 3: ...or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the...

Page 4: ...wer cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure...

Page 5: ...ide years of service and flexibility in today s background music and paging applications Key Features 200W Into 50V 100V and 4 Loads Automated Diagnostic System Test Push Here Diagnostic for 100V Dist...

Page 6: ...ult Indicator When testing the system using the PHD feature for proper wiring and amplifier loading this LED will illuminate Yellow if a fault is sensed in the audio speaker system See Using the PHD L...

Page 7: ...equencies by 6dB at 10kHz Rotating counter clockwise from the 12 00 position will decrease cut treble frequencies by 6dB at 10kHz 3 Input 1 Balanced Microphone or Line level signals connect to the and...

Page 8: ...ntom Power 24VDC is active when Input 1 is set to Mic mode and the switch is in the ON position Note Only use this feature if you are using condenser microphones otherwise leave in the OFF position DP...

Page 9: ...t section has a 3 position Phoenix connector for Mic or Line input signals and a 3 5mm stereo jack that is summed The level to the amplifier mix is controlled by Input 4 level located on the front pan...

Page 10: ...e up position the function is OFF or assigned to the feature stated when a switch is in the down position the function is ON or assigned to the feature stated Switch B DP SW 1 Mute Receive Input 6 Whe...

Page 11: ...vel Controls and PRE the Master Level on the front panel Set the system s maximum levels using the amplifier input level controls and then use the remote potentiometer as an attenuator from the maximu...

Page 12: ...quency impedance meter These are the best way to see if your speaker system is wired correctly for the amplifier B Run the PHD Self Diagnostic test Running a Self DiagnosticTest using the PHD Feature...

Page 13: ...speaker setting to make sure it is not set to a 4 8 or 16 ohm setting If one speaker is set to one of these settings it will cause a fault condition A simple and quick way to test this besides visual...

Page 14: ...e connected to the amplifier The LED should not steadily illuminate if a proper load is applied Note An occasional LED flash is okay during standard operation When LED is ON audible distortion may be...

Page 15: ...emote Level control port You can control Input 2 or Inputs 4 5 and 6 The AAPHD series remote level design is based on 10VDC return VCA type topology Connections to a 10K pot require three conductors w...

Page 16: ...ce for remote selection of 3 inputs without running audio signal from the amplifier This is ideal because the result is clean audio with no chance of picking up interference It is intended to be used...

Page 17: ...ch take the place of the front panel knobs After the amp has been installed and is operating as desired grasp the front panel knobs and pull straight out from the front panel Replace the knobs with se...

Page 18: ...m 18 Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Block Diag...

Page 19: ...s 1 6 Rear Panel Inputs Mic Line Balanced Qty 4 3 Position PHX Type 3 5mm Pitch Auxiliary Unbalanced Qty 2 RCA Auxiliary Unbalanced Qty 1 3 5mm Amp In Unbalanced RCA 600 Tone Controls Bass 6dB 100Hz T...

Page 20: ...150 Technical Data Inputs Total Qty 6 Frequency Response 50Hz 15kHz 3dB Thd N 0 5 Or Less At 1kHz Rated Output Input Sensitivity Impedance Input 1 2 3 4 Mic Mode 5mv No Trim 1200 Input 1 2 3 4 Line Mo...

Page 21: ...tlasSound com Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Page 22: ...sSound com 22 Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Page 23: ...tlasSound com Specifications are subject to change without notice Owner s Manual AA200PHD CE 200W Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 N...

Page 24: ...s warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be per...

Reviews: