MECHANICAL COLD PANS 

 

WCM/WCMD/WCMDC/WCML/WCMDL & WCMDCL SERIES 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------- 
 

INSTALLATION 

Provide the correct counter cut-out opening (see chart below) and drop in. The vinyl gasket assures complete 
seating. A non-toxic silicone seal may be used between the gasket and counter top (not required). 
Note: Units are supplied with a nipple and stop valve to be connected for draining. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

------------------------------------------------------------------------------------------------------------------------------------------- 
The unit should be level for draining purposes. When installing unit in a counter, it is recommended that the 
operator side of the counter be completely open for air circulation. When this is not possible, such as in an island 
counter, it is recommended that two grill openings are provided approximately 18” x 18” of free air for intake and 
exhaust at the opposite ends of the counter. 
The unit is supplied with a power cord and NEMA plug. Refer to the data plate on the compressor housing for the 
amperage and voltage information. Use a licensed electrician when installing power source. 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

OPERATION 

The unit is ready to operate as soon as it is plugged in. The thermostat has an off position and numbers from 1 
through 7, (number 7 is the coldest). The unit should be turned off every day after use and turned on one hour before 
serving. 

---------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

MAINTENANCE 

NEVER

 CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING 

COULD SCAR, MARK AND/OR CORRODE PANS. 

DO NOT

 USE STEEL WOOL OR ABRASIVE 

PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL 
RESIDUES. 

FAILURE TO MEET THESE

 

CONDITIONS WILL VOID WARRANTY

.  

CLEAN CONDENSER COIL REGULARLY. 

 

 

          MODEL NUMBER 

-   CUT-OUT SIZE 

WCM/ WCMD & WCMDC-1 

22 1/4 X 14 1/4 

WCM/ WCMD & WCMDC-2 

               22 1/4 X 28 

WCM/ WCMD & WCMDC-3 

22 1/4 X 41 3/4 

WCM/ WCMD & WCMDC-4 

22 1/4 X 55 1/2 

WCM/ WCMD & WCMDC-5 

22 1/4 X 69 1/4 

WCM/ WCMD & WCMDC-6 

               22 1/4 X 83 

WCML/ WCMDL & WCMDCL-2 

14 1/4 X 44 1/4 

WCML/ WCMDL & WCMDCL-3 

               14 1/4 X 66 

WCML/ WCMDL & WCMDCL-4 

14 1/4 X 87 3/4 