Program
Function
“Measured data”
Calls up the data currently measured and the status of a number of inputs.
“Counters”
Calls up the running hours, regulator (module) hours and number of motor starts.
“Test”
Display test.
“Modify parameters”
Modifies the settings for:
•
Parameters (e.g. loading and unloading pressures)
•
Protections (e.g. temperature shut-down level)
•
Service plans (timers for service plans)
•
Clock functions (automatic compressor start/stop/pressure band commands)
•
Configuration (time, date, display language,...)
“Service”
Calls up service plans and resets the timers after carrying out the service actions
belonging to a plan.
“Saved data”
Calls up the saved data: last shut-down, last emergency stop data.
“Unload/Load”
Loads and unloads the compressor manually.
3.7
Calling up menus
Description
Control panel
When the voltage is switched on, the Main screen is shown automatically.
Example of Main screen of ZR/ZT 55 up to ZR/ZT 90
“Compressor Outlet”
7.5 bar
.
“Automatically Loaded”
“Menu”
“Unload”
F1
F2
F3
After pressing the “Menu” (F1) key, the option “Status Data” will be followed by a horizontal arrow:
Instruction book
49
Summary of Contents for ZR-55
Page 12: ...General view of ZR 55 up to ZR 90 Full Feature with Energy Recovery Instruction book 11 ...
Page 13: ...Front view of ZR 55 up to ZR 90 Pack Instruction book 12 ...
Page 15: ...Views of ZT General view of ZT 55 up to ZT 90 Pack Instruction book 14 ...
Page 16: ...General view of ZT 55 up to ZT 90 Full Feature General view Instruction book 15 ...
Page 21: ...Flow diagram ZR Full Feature Instruction book 20 ...
Page 22: ...Flow diagram ZR Full Feature ND and ZR Full Feature with Low Load option Instruction book 21 ...
Page 23: ...Flow diagram ZT Instruction book 22 ...
Page 24: ...Flow diagram ZT Full Feature Instruction book 23 ...
Page 27: ...2 3 Condensate drain system Flow diagram ZR Instruction book 26 ...
Page 33: ...Flow diagram ZR Full Feature Instruction book 32 ...
Page 34: ...Flow diagram ZT Instruction book 33 ...
Page 41: ...Electric cabinet Typical example Typical example Instruction book 40 ...
Page 42: ...Drive motor M1 Drive motor M1 Instruction book 41 ...
Page 74: ...4 Installation 4 1 Dimension drawings Dimension drawing ZR Pack Instruction book 73 ...
Page 75: ...Dimension drawing ZR Pack with energy recovery Instruction book 74 ...
Page 76: ...Dimension drawing ZR Full Feature Instruction book 75 ...
Page 77: ...Dimension drawing ZR Full Feature with energy recovery Instruction book 76 ...
Page 78: ...Dimension drawing ZT Pack Instruction book 77 ...
Page 82: ...Installation proposal ZR Full Feature with energy recovery Instruction book 81 ...
Page 83: ...Installation proposal ZT Pack Instruction book 82 ...
Page 87: ...Instruction book 86 4 4 PANEL GA ZR 55 90 PACK ...
Page 88: ...Instruction book 87 ...
Page 89: ...Instruction book 88 ...
Page 90: ...Instruction book 89 ...
Page 100: ...Position of silica gel bags on ZT compressors Instruction book 99 ...
Page 102: ...Instruction book 101 ...
Page 122: ...7 2 Oil and oil filter change Control panel Oil system components ZR Instruction book 121 ...
Page 137: ...Instruction book 136 ...
Page 138: ...www atlascopco com ...