Instruction Manual
2954 2510 03
79
5.2.4
Air receiver
The air receiver(1) is tested according to official standards. Regularly have inspections carried out in
conformity with local regulations.
5.3
Safety valve
Following checks must be carried out:
•
A check of the opening of the lifting gear, twice a year.
This can be done by screwing the cap of the valve (2) anti-clockwise.
•
A check of the set pressure once a year according to the local regulations. This check cannot be
done on the compressor and must be carried out on a proper test bench.
Daily drain condensate.
(1)
(2)
All adjustments or repairs are to be done by an authorized representative of the
safety valve (2) supplier, see section
1.7 Specific safety precautions
.