![Atlas Copco XAS 185 KD7 T4 Instruction Manual Download Page 35](http://html.mh-extra.com/html/atlas-copco/xas-185-kd7-t4/xas-185-kd7-t4_instruction-manual_3001715035.webp)
- 35 -
unacknowledged alarms can be seen by pressing the
ALARM VIEW button
Pressing the ALARM VIEW button again, will bring you
back to the Main View.
Set Clock
Press the SETTINGS VIEW button
•
scroll to ‘1000 GENERAL SETTINGS’
•
press ENTER
•
scroll to ‘1290 DATE/TIME’
•
ENTER the Date/Time menu
•
scroll to the parameter you want to change
•
ENTER this parameter.
To change the ‘Month’, scroll to the preferred month and
press ENTER.
To change any other setting, the highlighted figure is
editable.
Scroll up/down and press ENTER to change. Use left/
right to shift between editable figures.
Now press BACK until you’re back in the Main View (or
in the menu you require).
Set Language
Press the SETTINGS VIEW button.
•
scroll to ‘1000 GENERAL SETTINGS’
•
press ENTER
•
scroll to ‘1300 LANGUAGES’
•
ENTER the LANGUAGES menu,
•
ENTER the ‘SETTINGS’ parameter
•
scroll to the preferred language
•
press ENTER.
Now press BACK until you’re back in the Main View (or
in the menu you require).
Set Units
Press the SETTINGS VIEW button,
•
scroll to ‘1000 GENERAL SETTINGS’
•
press ENTER
•
scroll to the unit you would like to change:
‘1340 TEMPERATURE UNITS’
‘1350 PRESSURE UNITS’
‘1360 FUEL FLOW UNITS’
•
ENTER the preferred menu
•
ENTER the ‘SETTINGS’ parameter
•
scroll to the preferred setting
•
press ENTER.
Now press BACK until you’re back in the Main View (or
in the menu you require).
Change Display Settings
Press the SETTINGS VIEW button
•
scroll to ‘1000 GENERAL SETTINGS’
•
press ENTER
•
scroll to ‘1310 DISPLAY BACKLIGHT’
•
ENTER the DISPLAY BACKLIGHT menu
•
scroll to the setting you would like to change
•
press ENTER.
To change a setting, the highlighted figure is editable.
Scroll up/down and press ENTER to change. Use left/
right to shift between editable figure.
Now press BACK until you’re back in the Main View (or
in the menu you require).
Go To Diagnostics
Press the SETTINGS VIEW button
•
scroll to ‘1000 GENERAL SETTINGS’
•
press ENTER
•
scroll to ‘1150 DIAGNOSTICS’
•
ENTER the Diagnostics menu,
•
ENTER the ‘ENABLE’ parameter
•
scroll to ‘ON’ and press ENTER.
Now the ECU will get power and one can perform ECU
diagnostics (read DM1 List, DM2 List, ECU values,
perform engine diagnostics, …).
Now press BACK until you’re back in the Main View (or
in the menu you require).
To leave Diagnostics, press the STOP button.
•
ECU warning 7009 will be active while in diagnos-
tics.
Summary of Contents for XAS 185 KD7 T4
Page 1: ...Engine Kubota V2403 CR E4 XAS 185 KD7 T4 Instruction Manual for AC Compressors English ...
Page 2: ......
Page 14: ... 14 Main Parts ...
Page 16: ... 16 Compressor regulating system Load Condition ...
Page 20: ... 20 Electric system CIRCUIT DIAGRAM 1310 3200 51 ...
Page 21: ... 21 ...
Page 44: ... 44 ALTITUDE UNIT PERFORMANCE CURVE ...
Page 50: ... 50 Adjustments and Servicing Procedures Adjustment of the Continuous Regulating System ...
Page 58: ... 58 ...
Page 59: ......
Page 60: ...www atlascopco com ...