- 80 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
Unit
U190 PACE
Absolute inlet pressure
bar
1
psi
14.5
Relative air humidity
%
0
Air inlet temperature
°C
20
°F
68
Normal effective working pressure
bar
10.5
psi
152.3
Designation
Unit
U190 PACE
Minimum effective receiver pressure
bar
3
psi
43.5
Maximum effective receiver pressure, compressor unloaded
bar
11.5
psi
166.7
Maximum ambient temperature at sea level 5)
°C
50
°F
122
Minimum starting temperature
°C
-10
°F
14
Minimum starting temperature, with coldstart equipment
°C
-20
°F
-4
Altitude capability
m
3000