8.17.5.6 Program, Monitoring data
Syntax:
Program[
<pgm name>
].Mon.
<parameter>
<
pgm name
>
= The name of the program
<parameter>
= See table below (and Bolt Monitoring for a description)
<parameter>
Data type
Description
MonStart
Short integer
Defines when to start monitoring. Takes the following
values:
0: Disabled
1: At cycle start
3: When a step that has the Start/restart monitoring flag
set is started (see Step
4: When the measured torque reaches the value
<MonStartTorqueVal>.
MonEnd
Short integer
Defines when to end monitoring. Takes the following values:
1: At cycle end
3: When the measured torque reaches the value
<MonEndTorqueVal>.
MonStartTorqueVal
Float
The torque value to reach before starting monitoring. Only
valid if <MonStart> is 4.
MonEndTorqueVal
Float
The torque value to reach before ending monitoring. Only
valid if <MonEndt> is 3.
MonBufAutoScale
Boolean
If True then the resolution of the monitoring buffer is auto
scaled.
MonResolution
Short integer
No of angle increment per buffer element in the monitoring
buffer. Valid only if <MonBufAutoScale> is False.
MonBufOverrunAllowed
Boolean
If True then monitoring buffer overrun is not regarded as an
error. Valid only if <MonBufAutoScale> is False.
Example:
Program[Pgm01].Mon.MonStart
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...