Tightening
9836 3521 01
273
6.5.2
Step
– Control
The
Control part
describes what main task to perform during the step.
The settings available for the Control part depends on the selected step. It is possible to change step by
the parameter
Step type
.
The checkbox
Synchronize
is used to select if the step should synchronize or not.
The check box
Start/restart monitoring
can be used in conjunction with the monitoring settings for the
program (Program Settings) in order to start or restart the recording into the monitor buffer. If restarted
everything recorded before this step is erased. See also the description of Bolt Monitoring.
Most step that run the spindle have a
Speed
parameter and a step
Direction
that can be set, note that the
direction is relative to the desired spindle direction.
It is also possible to select the torque and angle channel to use for step control with the
Torque channel
and
Angle channel
properties. The default value is
Auto
which is the first channel (Torque 1 or Angle 1) if
not disabled on the Spindle Set Up form.
Below the common properties follows the step specific properties, the following sub chapters list all
available step types and describe the parameters.